Corally TOROX 185 Скачать руководство пользователя страница 6

6

PLEASE NOTE :

•  For easy recognition, the motor beeps at the 

same time when the GREEN LED flashes.

•  When “N” (the number) is equal to or bigger 

than 5, we use a long flash to represent “5”. 
For example, the GREEN LED flashes a long 
flash (and the motor beeps a long beep at the 
same time) indicating you are in the 5th pro-
grammable item; if the GREEN flashes a long 
flash and a short flash (and the motor beeps a 
long beep and a short beep at the same time) 
indicating you are in the 6th programmable 
item; a long flash and two short flashes ( a 
long beep and two short beeps at the same 
time) indicating you’re in the 7th programma-
ble item and so on.

1. Programming The ESC With The Set Button

•  Restore the default values with the SET button 

Press and Hold the SET button for over 3 seconds anytime when the throttle trigger is at the neutral position (except 
during the ESC calibration and programming) can factory reset your ESC. RED & GREEN LEDs flash simultaneously 
indicating you have successfully restored all the default values within your ESC. Once you power the ESC OFF, and 
then back ON, the settings will be back in the default mode.

1. During the Start-up Process

•  The RED LED flashes rapidly, showing indications that the ESC doesn’t detect any throttle signal or the neutral throt-

tle value stored on your ESC may be different from the current value stored on the transmitter.

• The GREEN LED flashes “Number” times indicating the number of LiPo cells you have connected to the ESC.

2. In Operation

• RED & GREEN LEDs die out when the throttle trigger is in throttle neutral zone.
•  The RED LED turns on solid when your vehicle runs forward. The GREEN LED comes on when pulling the throttle 

trigger to the full (100%) throttle endpoint.

•  The RED LED turns on solid when you brake, the GREEN LED will also come on when pushing the throttle trigger to 

the full brake endpoint and setting the “maximum brake force” to 100%.

• The RED LED turns on solid when you reverse your vehicle.

3. When Some Protection is Activated

•  The RED LED flashes a short, single flash and repeats (

,

,

) indicating the low voltage cutoff protection is acti-

vated.

•  The GREEN LED flashes a short, single flash and repeats (

,

,

) indicating the ESC thermal protection is activat-

ed.

•  The GREEN LED flashes a short, double flash and repeats (

☆☆

,

☆☆

,

☆☆

) indicating the MOTOR thermal protection 

is activated.

ESC PROGRAMMING

FACTORY RESET

LED STATUS

SIMPLIFIED DECLARATION OF CONFORMITY

MANUFACTURER : 

Team Corally

 hereby declares that the speedcontroller system type 

TOROX 185

 complies with the Directive 

2014/53/EU.
The full text of the EU Declaration of Conformity is available at the following Internet address:  

www.corally.com 

Team Corally, Geelseweg 80, B-2250 OLEN, Belgium, [email protected]

Содержание TOROX 185

Страница 1: ...TOROX 185 INSTRUCTION MANUAL www corally com C 54011 ...

Страница 2: ... be destroyed and your engine may be damaged We recommend setting the ESC Thermal Protection to 105 C 221 F this is the internal temperature of the ESC Please remove the ESC cooling fan before exposing the vehicle to liquids and dry it completely immediately after use Always disconnect the batteries after use as the ESC will always consume power if connected to the battery even if the ESC is off A...

Страница 3: ...urning ON the transmitter with the ESC turned OFF but connected to a battery Holding the SET button and press the ON OFF button the RED LED on the ESC starts to flash Note 1 the motor beeps at the same time and then release the SET button immediately The ESC will enter the programming mode if the SET button is not released in 3 seconds please restart from step 1 3 Set the neutral point the full th...

Страница 4: ...in The reverse function will not work if your car does not come to a complete stop The vehicle only reverses after the motor stops This method is for preventing vehicle from being accidentally reversed 2 LIPO CELLS We recommend to set this function manually instead of the Auto Calc default setting which means calculating the LiPo cells a utomatically The ESC can only identify 3S 4S 6S and 8S LiPo ...

Страница 5: ...vos otherwise your servos may not function normally due to insufficient voltage Setting 7 4V It s applicable to high voltage servos Do not use this option with ordinary servos otherwise your servos may be burnt due to high voltage 8 BRAKE FORCE The ESC provides proportional braking function the braking effect is decided by the position of the throttle trigger It sets the percentage of available br...

Страница 6: ...l or the neutral throt tle value stored on your ESC may be different from the current value stored on the transmitter The GREEN LED flashes Number times indicating the number of LiPo cells you have connected to the ESC 2 In Operation RED GREEN LEDs die out when the throttle trigger is in throttle neutral zone The RED LED turns on solid when your vehicle runs forward The GREEN LED comes on when pul...

Страница 7: ...ool down before using it again The motor stuttered but couldn t start 1 Some soldering between the motor and the ESC was not good 2 The ESC was damaged some MOSFETs were burnt 1 Check all soldering points please re solder if necessary 2 Contact the distributor for repair or other customer services The vehicle run forward and brake but could not reverse 1 The throttle neutral position on your trans...

Страница 8: ...Team Corally Geelseweg 80 2250 Olen Belgium Tel 32 14 25 92 94 info corally com www corally com ...

Отзывы: