CopperOptics PairGain PG-Flex FLC-703 Скачать руководство пользователя страница 4

Section 363-703-103
Revision 01

Page 4

4.  CERTIFICATION

4.01

FCC Compliance. The FLC-703 Channel Unit
complies with the limits for Class A digital devices

pursuant to Part 15 of the FCC rules. These limits are
designed to provide reasonable protection against harmful
interference when the equipment is operated in a commercial
environment. This equipment generates, uses and can radiate
radio frequency energy and, if not installed and used in
accordance with the instruction manual, may cause harmful
interference to radio communications. Operation of this
equipment in a residential area is likely to cause harmful
interference in which case the user will be required to correct
the interference at his own expense.

4.02

Refer to the installation section of the appropriate
instruction manual for the unit you are installing to

get information on:

• 

Cabling

• 

Proper connections

• 

Grounding

• 

Line power

4.03

All wiring external to the product(s) should follow
the provisions of the current edition of the National

Electrical Code.

5.  WARRANTY

5.01

PairGain Technologies warrants this product to be
free of defects and to be fully functional for a period

of 5 years from the date of original shipment, given proper
customer installation and regular maintenance. PairGain will
repair or replace any unit without cost during this period if
the unit is found to be defective for any reason other than
abuse or improper use or installation.

5.02

This module should not be field repaired. If it fails,
replace it with another unit and return the faulty unit

to PairGain for repair. Any modifications of the unit by
anyone other than an authorized PairGain representative will
void the warranty.

5.03

If a unit needs repair, call PairGain for a Return
Material Authorization (RMA) number and return

the defective unit, freight prepaid, along with a brief
description of the problem, to:

PairGain Technologies, Inc.
2120 Ritchey St.
Santa Ana, CA 92705-5101
ATTN:  Customer Repair Facility
(800) 638-0031

5.04

PairGain will continue to repair faulty modules
beyond the warranty program at a nominal charge.

Contact your PairGain sales representative for details and
pricing.

B.  FUNCTIONAL DESCRIPTION

6.  OPERATIONAL CAPABILITIES

6.01

The FLC-703 Channel Unit provides 8 POTS
interfaces to the CO switch. The card performs the

interface function between the analog POTS circuit and the
internal digital PCM bus. In addition, each card:

• 

Converts analog signals to 64 kbps 

µ

-Law PCM

digital format

• 

Detects ringing voltage

• 

Detects forward disconnect

• 

Detects a subscriber test access signal

• 

Provides loop closure

• 

Pair Gain Test Controller (PGTC) compatibility

6.02

A block diagram of the FLC-703 Channel Unit is
shown in Figure 3. One 8-Channel COT POTS Unit

supports eight POTS interfaces.

6.03

A status LED is associated with each line to indicate
whether the line is off-hook, idle, ringing, or being

tested. A common fault LED indicates a general fault has
been detected on the card and it should be replaced.

6.04

Test access connections to a specific line circuit are
made through the maintenance terminal or by the

CO switch applying the appropriate voltages on the
subscriber line (see paragraphs 2.01 through 2.04).

Содержание PairGain PG-Flex FLC-703

Страница 1: ...SCRIPTION AND FEATURES 2 2 APPLICATIONS 2 3 SPECIFICATIONS 3 4 CERTIFICATION 4 5 WARRANTY 4 B FUNCTIONAL DESCRIPTION 6 OPERATIONAL CAPABILITIES 4 7 FRONT PANEL 5 C INSTALLATION AND TEST 8 UNPACKING 5...

Страница 2: ...lifies troubleshooting Pair Gain Test Controller PGTC Compatibility List 3 only 2 APPLICATIONS 2 01 Subscriber Drop Testing For subscriber drop testing from the central office PG Flex is able to selec...

Страница 3: ...signal between tip and ring leads with an amplitude from 65 Vrms to 104 Vrms and frequency between 16 Hz and 50 Hz as a ringing signal This signal may be superimposed on a dc component of 36 0 Vdc to...

Страница 4: ...eplace it with another unit and return the faulty unit to PairGain for repair Any modifications of the unit by anyone other than an authorized PairGain representative will void the warranty 5 03 If a...

Страница 5: ...as follows 1 Unpack each container and visually inspect it for signs of damage If the equipment has been damaged in transit immediately report the extent of damage to the transportation company and to...

Страница 6: ...the COT Shelf All LEDs on the Channel Unit will turn on for approximately second then scan from top to bottom then flash all on then off b After the system has powered up established HDSL synchronized...

Страница 7: ...Unit If ringing is present on other lines check for high resistance shorts on the subscriber drop If no high resistance shorts replace the RT Channel Unit 2 If ringing isn t present on a circuit term...