350-611-101-01
March 17, 1998
Revision
01
HLU-611
List
1
PairGain
Engineering - Plant Series
17
S
PECIFICATIONS
Power Consumption
14 Watts (typical); 18 Watts (maximum)
Heat Dissipation
6 Watts (typical) 8 Watts (maximum)
Mounting
220 Mechanics
Dimensions
Height:
5.6” (15 cm)
Width:
1.4” (3.5 cm)
Depth:
10” (25.4 cm)
VER
HLU Software
Version #
This is displayed during the System Settings
review mode. Depress the
MODE
button for 3
seconds to enter System Settings review mode.
LIST 0xL
HLU’s List #
Displayed during System Settings review mode
defined above.
FRM
Frame: SF, ESF, UNFR,
NONE
Defines the type of frame pattern being received
from the DSX-1. Displayed during System
Settings mode defined above.
CODE
Line Code: AMI, B8ZS
This is the line code that the HLU is set to receive
and transmit at its DSX-1 interface. Displayed
during System Settings mode defined above.
DS0
DS0 Blocked Channels
Indicates status of DS0 blocked channels. NONE
indicates no channels are blocked. BLK indicates
some channels are blocked.
Four-Character Diagnostic Messages
(Continued)
Message
Full Name
Description