Tips for Assembly

Before You Begin:

Ÿ

Lay out and identify all of the included parts. 

Ÿ

according to together in one bag.

The hardware has been packed 

Ÿ

Read the assembly guide over once to familiarize yourself with them.

As You Assemble the Unit:

Ÿ

Follow the steps in sequence.

Ÿ

Before beginning each step, find the part(s) that you need for that step.

Ÿ

the 

The title of each step states what you will be doing. Review the text and 
pictures as you build the unit.

Please read the warnings below for important safety information regarding your product. Failure to read these 
warnings or to follow the instructions below could result in personal injury or damage to your product that could 
void your warranty. 

Ensure that any cables extending across the floor to your product are properly bundled and 
marked to avoid tripping or falling which may lead to personal injury.

Cable Trip 
Hazard

Indoor Use
Only

This product is intended for indoor comercial use only. To reduce the risk of fire or electric 
shock, do not expose this product to rain or moisture. The internal components are not 
sealed from the environment.

In its unassembled state, this product contains parts that can be hazardous to small children. 
This product should be assembled by an adult.

Small Parts

This product is to be used under the supervision of an adult.

Adult  
Supervision

Do not climb on, hang from or suspend objects from any components of your product 
unless otherwise specified. 

Climb
Hazard

Read your power strip electrical specifications. Only plug in devices that are approved for 
use with this power strip. Connect the supplied power strip directly to a wall outlet.

Do not connect to another power strip or use an extension cord.

 Turn off power strip 

before unplugging. Unplug when not in use.

Power Strip
Specifications

Read the electrical specifications of any electronic equipment you are using with your 
Copernicus products. Failure to read these specifications and follow their instructions could 
result in damage to your equipment or personal injury.

Electronic 
Equipment

Do not install or use the electrical components of this unit during a lightning storm.

Electrical
Shock

Important Information! Warning!

The symbol denotes a 
step needing extra 
attention to ensure it is 
done correctly.

Watch for These Helpful Symbols

:

For safety, please have 
someone help you when 
working on steps 
displaying this symbol.

2-Person Task

Содержание iRover2 IFP500

Страница 1: ...s unassembled state small parts present a hazard To be used under direct supervision of an adult This cart is intended for institutional use Warning Supports a maximum screen size of 90 Warning For us...

Страница 2: ...have all the information we need to make any future warranty claims quick and easy Please visit www copernicused com warranty and complete the form within 10 business days from product assembly By reg...

Страница 3: ...ponents are not sealed from the environment In its unassembled state this product contains parts that can be hazardous to small children This product should be assembled by an adult Small Parts This p...

Страница 4: ...10065 2x 5 Caster 410066 2x Protective Handle Extension Right 331751R 2x Protective Handle Extension Left 331751L 2x Power Strip 25515 1x Electric Lift Adapter not shown Remote not shown 25525 1x Lapt...

Страница 5: ...re for VESA Mounting D 10 24 x 1 2 Self Tapping Screw 8x 4302012 3 8 Lock Nut 6x 430122 I 1 4 Lock Washer 14x 43010 H G 5 16 Lock Washer 4x 43025 10 24 Lock Washer 8x 4301002 F M6 x 15mm VESA Screw 4x...

Страница 6: ...e Frame 1x Base Foot Left 1x Base Foot Right 1x 4x 4x 4x 4x 5 Locking Caster 2x 2 Person Task 4x 2 Person Task Install locking casters on back of unit and tighten using supplied Caster Wrench Front Ba...

Страница 7: ...ed Not to Scale Actual Size 3 Install Moving Frame You will need Not to Scale Actual Size Moving Frame 1x Electric Lift 1x Moving Frame faces front of unit A 2x 2x Remove appliance tape from top bushi...

Страница 8: ...of unit 5 You will need Not to Scale Actual Size T 2x 2x Bottom Shelf 1x Install Bottom Shelf 6 You will need Not to Scale Actual Size Power Strip 1x Small Tub 1x Attach Power Strip and Install Tub A...

Страница 9: ...Riser 2x H I N O P Q Screwdriver Phillips 2 or 3 Showing SMART MX265 Flat Panel 4x or or or or 4x Check your flat panel owners manual to determine correct VESA screw size and torque specifications to...

Страница 10: ...D 8x 8x D G G D D G G D D G G D D G G D Install Flat Panel Mount Stretchers Flat Panel Mount Stretcher 2x Screwdriver Phillips 2 or 3 Do not secure in these holes they are used for attaching an option...

Страница 11: ...onal Products Inc 9 Actual Size You will need Not to Scale 2 Person Task 4x 4x C H Lock all casters before attaching flat panel to cart C H Screwdriver Phillips 2 or 3 Secure Flat Panel To Cart Insert...

Страница 12: ...to Scale Actual Size Protective Handle Extension Right 2x Protective Handle Extension Left 2x Protective Handle Front 2x 4x 4x 4x Allen Key 2x L M M R R K 4x M R M R M R Position handle close to your...

Страница 13: ...need Not to Scale Actual Size Use remote hook to hang remote on cart Electric Lift Power Adapter Remote 1x Connect and secure your electric lift cable 11 You will need Not to Scale Actual Size Laptop...

Страница 14: ...uring Your Device You will need Not to Scale Actual Size Laptop Tray 1x 13 Assemble Laptop Tray You will need Not to Scale Actual Size 20 lbs Weight Limit Laptop Tray Bracket Hardware 1x 3x S T 3x S T...

Страница 15: ...ucational Products Inc 15 Attaching Laptop Tray To Cart You will need Not to Scale Actual Size Laptop Tray 1x In use Position On Back of Cart 20 lbs Weight Limit In use Position On Left or Right Handl...

Страница 16: ...Not to Scale Actual Size Hook Loop Straps 6x USB Cable Flat Panel Power Cable Laptop Computer Power Cable VGA HDMI Cable items not included with IFP500 Laptop tray can install on both sides Raise fla...

Страница 17: ...t included 18 Final Assembly Checks You will need Not to Scale Actual Size Caster Wrench 1x Check entire assembly for loose parts tighten all casters bolts screws and nuts Tighten all casters using su...

Страница 18: ...B100 IWB102 Must be lower than doorway ONLY ADULTS SHOULD MOVE THIS UNIT APPLY MOVING FORCE ON NARROW DIMENSION NEVER APPLY FORCE AT TOP ALWAYS PUSH NEAR MIDDLE PUSH DON T PULL Warning Can tip over re...

Отзывы: