![COPAL ELECTRONICS PA-870 Series Скачать руководство пользователя страница 3](http://html1.mh-extra.com/html/copal-electronics/pa-870-series/pa-870-series_quick-start-manual_2665944003.webp)
3
5.OUTLINE DIMENSIONS
6. SPECIFICATIONS
5.1 Outline dimentions
5.2 Drip-proof cover type
5.3 Rear
Please make sure that the drip-proof cover is properly placed
over the main body and the cable.
30
17
(47.5)
15
6.5
26
Label
Housing
(SUS316)
0
−0.4
Pressure port
φ4
2000 ±20
φ5
7
R1/4(PT1/4)
(SUS316)
Hysteresis setting VR
Indicator LED
Pressure setting VR
PA−870/PA−878
PS87
Drip-proof cover
6.1 General specifications
Item
Operating temp.range
Compensated temp.range
Operating humidity
Stirange temp.
Pressure medium
Cable
Drip-proof structure
Net Weight
Specifications
-10〜75℃
0〜50℃
35〜85%RH(No condensation)
-20〜90℃(Atmospheric pressure,humidity 65%RH maximum)
Corrosive gases/liquids compatible with SUS316 and Hastelloy
Ñ
C-22
3 - core shielded cable(PA-870,PA-878)
4 - core cable(PS87)
Without drip-proof cover:IP-54, With drip-proof cover:IP-65
Approx.190g
6.2 Power
Item
Supply voltage
Consumption current
Specifications
10.8〜26.4V DC
10mA maximum (PA-870)
15mA maximum(PS87)