COPAL ELECTRONICS PA-870 Series Скачать руководство пользователя страница 1

Pressure Transducers with Amp.

INSTRUCTION MANUAL

 Ver.2.0

PA-870/PA-878

series

Pressure Switch

PS87

series

1

Handling Notes for Safety use

CAUTION

…This caution mark describes when there is a possibility that under may suffer from damage or Physical damage  
 may occur if the product is used improperly.

Caution

Caution

Caution

Before operating our product, read this manual thoroughly.

 

You may not understand all of the explanations the first time thorough, but be on the lookout for 

any special directions.

 

 Piping:

 

  Install the product by screwing the pressure port to the matching fitting. 

  During this operation, put the wrench only to the hexagonal portion and do not give any unnecessary force to the main body and the lead wire. 

 Wiring:

 

  The connection of wiring is as shown in the table below. 

 

 

 

 

 

 

 

 

 

 Others:

 

   

_

This product can be used for liquids/gases compatible with SUS316 and Hastelloy

Ñ

 C-22. 

   

`

 Never insert a foreign matter such as wire through the pressure port. 

   

a

 Never take in the over-pressure exceeding the maximum pressure. 

   

b

 Never short-circuit the switch output to the other terminals, nor connect them to the low impedance load that would allow the output current over 100mA.  

     These conduct might damage the internal circuitry. 

   

c

 Use a stable DC power supply for the power source. A surge absorbing circuit (diodes, varistor, etc.) is necessary if an inductive load such as a relay or   

  solenoid is connected to the power line and/or to the switch output(s). The FG terminal on the unit power supply should be earthed. 

     (Please refer to the following diagrams) 

Thank you for purchasing NIDEC COPAL ELECTRONICS 

CORP. product. 

In  order  to  use  the  product  correctly  and  most 

appropriately,  please  completely  read  this  manual  before 

use and keep it for future reference.

Nishi-Shinjuku Kimuraya Bidg. , 7-5-25 

Nishi-Shinjuku  Shinjuku-ku  Tokyo 160-0023, Japan    Phone.:(03)

 3364-7055

For more detailed information please ask for the 

nearest distributor or the following sales center.

Earthing to FG terminal

The terminal FG is grounded

Surge sbsorbing Circuit

Switching Power Supply

Power Line

Power(+)

Relay 

or 

Solenoid

ex. Diodes, Varistor

DC output

FG

AC input

*Never short-circuit the switch output(s) to the other terminals, 

nor  connect  them  to  the  low  impedance  load  that  would  allow 
the  output  current  over  100mA.  These  conduct  might  damage 
the internal circuitry.

PA-870

PA-878

PS87

P/N

Wire color

Red 
Black 
White 
Green 
Gray(Shield)

Power (+) 

Common 

Analog output 

None 

Fitting

Power (+) 

No Connection 

Output 

None 

Fitting

Power (+) 

Power (-) 

Switch output (+) 

Switch output (-) 

None