![Copa eomix Скачать руководство пользователя страница 30](http://html.mh-extra.com/html/copa/eomix/eomix_user-and-installation-manual_2665933030.webp)
03
Drawing 1.3.1
The Room At The
Connection B3 Type
COPA Eomix Wall Hung Gas Boiler User and Installation Manual
1.3. Chimney Connection
• The appliance is a C3 type
appliance with hermetic flue
systems. It can be used as B3
type under condition of
Drawing 1.3.1. The room must
be 1 m3 more for each 1 kW
capacity and there should be
sufficient aerations.
• A standart flue kit with 800 mm
length is given with the boiler.
But also, different flue connecti
ons as shown on Drawing
1.3.2-1.3.3 and 1.3.4. The given
length on Drawing 1.3.2-1.3.3
and 1.3.4 are gross lengths
Please check identical length
table for net valves.
28
Max. Equivalent
Distance: 6 m
Drawing 1.3.2
Max. Equivalent
Distance: 15 m
Drawing 1.3.3
(Coaxial 60/100 Ø)
(Seperate 80 Ø)
Coaxial 60/100
6 m
1 m
0.5 m
Coaxial 80/125
20 m
0.5 m
0.25 m
Maximum Length
Identical Length For 90° bending
Identical Length For 45° bending
Coaxial Length Table
Losses
Identical Length For Seperate Chimney Systems
EOMİX
Maximum Length
60 m
Seperate Chimney Systems
Fresh Air
Flue
Vertical Horizontal
Ø 80
Bending
Pipe
1 m
45°
90°
90°
Test
1,2
1,5
1,5
1,8
2
2
1
1,6
2