The drive should contain only one partition, and the Offset value should be non-zero as shown below. 

 

DISKPART> list partition 
  Partition ###  Type              Size     Offset 
  -------------  ----------------  -------  ------- 
  Partition 1    Primary           1910 MB    64 KB 

 

You can now 
format the drive using the diskpart utility. 

 

If the 

or if there is more than one Partition, as indicated in the examples below, follow steps 6 and 

7 below to re-configure the drive.

 

Partition ###  Type              Size     Offset 
  -------------  ----------------  -------  ------- 
Partition 1    Primary           1911 MB      0 B 

 

Partition ###  Type              Size     Offset 
-------------  ----------------  -------  ------- 
Partition 1    Primary            100 MB    64 KB 
Partition 2    Primary           1810 MB   101 MB

 

 

6.

 

 

 

DISKPART> list disk 
  Disk ###  Status         Size     Free     Dyn  Gpt 
  --------  -------------  -------  -------  ---  --- 
  Disk 0    Online          232 GB      0 B 
* Disk 1    Online         1911 MB      0 B 
 
DISKPART> clean 
DiskPart succeeded in cleaning the disk. 
DISKPART> list disk 
 
  Disk ###  Status         Size     Free     Dyn  Gpt 
  --------  -------------  -------  -------  ---  --- 
  Disk 0    Online          232 GB      0 B 
* Disk 1    Online         1911 MB  1910 MB 

 

7.

 

command, and note that there is only one partition, and that the offset is non-zero. 

 

DISKPART> create partition primary 
DiskPart succeeded in creating the specified partiti 
Type              Size     Offset 
  -------------  ----------------  -------  ------- 
* Partition 1    Primary           1910 MB    64 KB 
 

8.

 

Finally, the drive can be formatted using the  diskpart  command line. The file system format should be selected 

w the label 

 

 

Содержание Elpro 450U-E

Страница 1: ...Version 1 0 12 Beta7 Cooper Bussmann Read and Retain for Future Reference...

Страница 2: ...ass B digital device pursuant to Part15 of the FCC rules Code of Federal Regulations 47CFR Part 15 Operation is subject to the condition that this device does not cause harmful interference Part 90 Th...

Страница 3: ...The products are designed to operate in the presence of noise and interference however in an extreme case radio noise and interference could cause product operation delays or operation failure Like a...

Страница 4: ...system make sure you have considered the security aspects of your installation carefully Release Notice This is the July 2012 release of the 450U E Ethernet Modem User Manual version 1 0 12 Beta7 whi...

Страница 5: ...etwork Settings Webpage Fields 27 SPANNING TREE PROTOCOL ALGORITHM 28 3 7 SECURITY MENU 28 3 8 WEP 128 bit 29 Encryption Keys 1 to 4 29 Default WEP Key 29 WPA2 29 WPA Enterprise 29 Authenticator AP Co...

Страница 6: ...sters 63 MONITOR RADIO COMMS 64 4 7 MONITOR IP COMMS 64 4 8 SYSTEM TOOLS 65 4 9 Setting a 450U E to Factory Default Settings 65 MODULE INFORMATION CONFIGURATION 65 4 10 Module Information Webpage Fiel...

Страница 7: ...em is capable of passing VLAN tagged frames The 450U E has a standard RJ45 Ethernet connection which will operate at up to 100Mbit sec The module will transmit the Ethernet messages on the wireless ba...

Страница 8: ...nt is configured at the LAN end although the wireless link will still work if the Client is at the LAN end An Access Point can connect to multiple Clients In this case the 450U E Clients which do not...

Страница 9: ...dge connects devices within the same Ethernet network for example extending an existing Ethernet LAN A Router The IP addresses for the Ethernet and the Wireless sides must be different In this example...

Страница 10: ...d applications are required the 450U E have many sophisticated features which can be adjusted if need be First read Chapter This will explain the connections that are required for successful operation...

Страница 11: ...ees to the radio path A 450U E can achieve up to 50 Km 31 miles with a directional antenna attached To achieve the maximum transmission distance the antennas should be raised above intermediate obstru...

Страница 12: ...ntenna cable configuration is determined by adding the antenna gain and the cable loss For example an 8dBi antenna with 10 meters of Cellfoil 2 5dB has a net gain of 5 5dB 8dB 2 5dB Installation tips...

Страница 13: ...ansmitting to a vertically mounted omni directional antenna then the Yagi elements should be vertical If the Yagi is transmitting to another Yagi then the elements at each end of the wireless link nee...

Страница 14: ...when unit is powered on 7 RTS In Request to Send 8 CTS Out Clear to send 9 RI Ring indicator RS485 Serial Port The RS485 port provides a communication link from the 450U E unit to a host device using...

Страница 15: ...aded via the USB but through the web interface The procedures for performing a full firmware upgrade and the patch file upgrade can be found in Section Appendix A Firmware Upgrades USB B Device connec...

Страница 16: ...e Digital Output will override the Digital Input operation i e if the output is activated while the DIO is being read the indication will show the input as being on 1 Digital Input When used supports...

Страница 17: ...d the TX LINK LED is on GREEN For a Client of the web interface After the link is established data may be transferred in both directions The Access Point will act as a master unit and will control the...

Страница 18: ...EN different intensity Analog input current loop dim 4mA bright 20mA The Ethernet RJ45 connector on the end of the module incorporates two indication LEDs The LINK LED which comes on to indicate a con...

Страница 19: ...a wireless link is best measured in terms of the maximum throughput that can be achieved The recommended method of measuring throughput is to use an external Modbus Client to poll the internal Modbus...

Страница 20: ...set the switch back to the RUN position and cycle power at the conclusion of configuration for resumption of normal operation The default factory configuration of the 450U E is Client Bridge IP addres...

Страница 21: ...operation Power up the 450U E module following description is for Windows XP earlier Windows operating systems have similar settings Select Internet Protocol TCP IP and click on Properties On the Gene...

Страница 22: ...U E Network address to match the local network For this method you will need to determine what IP address Gateway address and Netmask to assign to the 450U E so rrect settings for your network E g If...

Страница 23: ...pass proxy for local addresses Enter the IP address for the 450U E into the Internet Explorer Address bar e g http 10 10 0 6 which is the IP address you temporarily configured with the ifconfig comman...

Страница 24: ...er a number of configuration parameters before the modems can be used these include Transmit and Receive Frequency as per the country regulation Radio transmit power level Operating mode System Addres...

Страница 25: ...st Selections available are 9600 and 19200 kbps for wide band radios or 4800 9600 kbps for narrow band The Transmit Data Rate only applies to the Transmit messages as the radio can receive on either d...

Страница 26: ...ng or be configured as a routing network to limit unnecessary broadcast traffic being sent over the radio Refer to Section 3 14 Filtering this can be implemented A system of 450U E All 450U E d Radio...

Страница 27: ...t string 1 to 31 characters in length Select a text string which identifies your system Desired BSSID To force a client station to always connect to the same Access Point enter the MAC address of that...

Страница 28: ...link fails the other link will automatically start transferring the wireless data The Spanning Tree Protocol implemented is IEEE 802 1d compatible The algorithm forms a loop free network by blocking...

Страница 29: ...00 Default WEP Key One of the four keys may be selected as the default key and is used to encrypt transmitted messages from the configured unit A 450U E can receive and decrypt a message from a modul...

Страница 30: ...ant If WDS interfaces are used it is possible for one 450U E to act as both an Authenticator and a Supplicant however in this situation only one set of user credentials can be entered for all Supplica...

Страница 31: ...ee Protocol Algorithm Router Operation Routed Network A router joins separate IP sub networks together The router has different IP addresses on its wired and wireless ports reflecting the different IP...

Страница 32: ...you can select when configuring the TX and RX frequencies The steps sizes available are 5Khz or 6 25KHz Transmit Frequency The Frequency that you wish to configure for the radio Transmitter Frequency...

Страница 33: ...dbus depending on the radio baud rate 70 improvement for web page download 40 improvement if using FTP download Serial Port Configuration 3 11 The 450U E has an RS 232 and an RS 485 port which is used...

Страница 34: ...ation as they are bridged with the standard wireless interface that is used for connections to associated clients All of the WDS interfaces on the one Access Point may be bridged if required WDS bridg...

Страница 35: ...client will connect to For AP mode clients must configure their WEP Key 1 to the same value as this key and select the Default WEP Key to be WEP Key 1 There are many different ways to setup wireless n...

Страница 36: ...ming with WDS Access Points Another common use for WDS is extending the range across a large wireless network but allowing roaming connections between access points or being able to switch to the next...

Страница 37: ...routers and in some cases when WDS router interfaces are used If more than one 450U E allows for up to 100 routing rules to be configured A routing rule specifies a destination network or host IP add...

Страница 38: ...169 254 109 40 as this is the IP address of the wired side of the LAN B 450U E Any message coming in with a 192 168 0 X IP address will be directed across the wireless interface to LAN A The Routing...

Страница 39: ...e address and the destination address of the message If either address match then the rule is activated ARP filtering applies only to ARP request packets typically these are broadcast packets which ar...

Страница 40: ...s not IP will be passed and this could include Netbios IPX PPP etc These protocols could be more effectively filtered by using MAC filtering or configuring the modems in a Router configuration instead...

Страница 41: ...requests for known units to pass or blocking ARP requests for high use addresses Blacklist will prevent all listed devices from accessing the module and using the radio link Whitelist will allow devi...

Страница 42: ...Gateway the 450U E can transfer I O to from almost any combination of Modbus TCP or RTU devices Modbus RTU Master ports Each serial port has a number of parameters that can be adjusted for different...

Страница 43: ...er location for the previously polled values to be stored It will also allow an external Modbus TCP Client DCS or Scada to monitor the stored I O values from units A C via the extended wired or wirele...

Страница 44: ...store the communication status of the specified transaction The Specified register will be set to 0 if communications is successful 0xFFFF if there is no connection to the specified server or 0xFFxx...

Страница 45: ...s Error Codes Note When entering the Local or Destination registers you do not need to enter in the full Modbus Address i e 30001 or 10001 only the I O address is needed as the Function Code determine...

Страница 46: ...ted to the modem I O Configuration Configuration of the physical I O Analog Input or the Digital Input output is done by accessed from the main right hand web links Selecting the to change the name of...

Страница 47: ...10002 and VSupply setpoint is located at register 10003 Upper Setpoint This parameter is the upper control point value that is used in conjunction with the Lower Setpoint to turn on and off the Analog...

Страница 48: ...re are over 5000 x 16bit general purpose registers that are available for Modbus including the onboard Analog Digital Input Output and are shared with both Modbus Client and Server Along with the phys...

Страница 49: ...rt must be configured The default serial parameters of the port should be 9600 N 8 1 which match the defaults of the 115S serial expansion modules These parameters can be changed to increase poll spee...

Страница 50: ...130 seconds which is a little over two times the 1 minute update period from the sending module If after 130 seconds the module still has not received an update from the other module register below I...

Страница 51: ...starts up with Configuration Examples 3 17 Extending a wired network Bridged Network Access Point Configuration Connect straight through Ethernet cable between PC and 450U E Ensure configuration PC an...

Страница 52: ...m Address ESSID and Encryption key are the same as the Access Point Set the Operating Mode to Client Change the IP addresses to 192 168 0 101 When complete set the dipswitch back to RUN ave Client 2 C...

Страница 53: ...configured for WPA2 AES and will require an encryption key which will also need to be the same on all radios in the example Change the IP addresses to 192 168 0 200 Leave the Subnet masks at the defa...

Страница 54: ...Elpro Technologies 450U E Wireless Ethernet Modem Device Server User Manual 54 www cooperbussmann com wirelessresources Rev Version 1 0 12 Beta7 Figure 61 Example Repeaters...

Страница 55: ...open circuit I O GREEN varying intensity Analog input current in circuit Dim 4mA bright 20mA The green OK LED on the front panel indicates correct operation of the unit This LED turns red for a number...

Страница 56: ...mum data rate Note When updating the Connectivity webpage it is necessary to hold down the ctrl key while pressing the refresh button to ensure the most up to date information is displayed Connectivit...

Страница 57: ...mple cost effective means for more advanced analysis By monitoring traffic on the wired Ethernet a better idea of regular traffic can be discovered Network Analysis programs make configuration of a fi...

Страница 58: ...buted to poor RSSI which could be confirmed on the Connectivity page Channel Utilisation Graphs Channel Survey screen displays a graph showing the percentage of time that a channel is being utilised b...

Страница 59: ...data to be displayed which is useful for diagnosing channel utilisations problems The default selection on the custom page will display the total percentage of transmitted frames over a 60 second peri...

Страница 60: ...specifically addressed to this modem RX to other radios The percentage of time receiving valid Elpro messages addressed to other radios within the system RX acknowledgements The percentage of time re...

Страница 61: ...crease in communications Network Diagnostics 4 5 Network Diagnostics allows you to check the communications path to other modules within the system Ping Ping is a standard Network instruction that sen...

Страница 62: ...n E g 1 2500 enter the address location count and value and then press the E g Write to Register 1 with a count of 1 and a value of 1 will turn the Local Digital Output on To Read an Analog register l...

Страница 63: ...r will be at register location 30019 2 20 30059 Modbus Module Type will be at register location 30020 2 20 30060 These Expansion I O Error registers display the following 115S Status Codes Hex code 00...

Страница 64: ...sses along with some other IP Comms data More information on standard IP Comms can be found on the internet Time Message Time Stamp Time from when module was last started Message Type Displays if mess...

Страница 65: ...OK LED will turn green when the reset sequence is complete When complete you should be able connect to the modules default IP address which will be displayed on the label on the bottom of the module M...

Страница 66: ...guration Protocol allows DHCP Clients to automatically obtain their IP Address at start up This simplifies network administration as there is no need to manually configure each device with a separate...

Страница 67: ...a designated address and waiting for a response The basic operation of Ping can be performed by following these steps in any Windows operating system There will be a certain directory specified unique...

Страница 68: ...ered using the command ipconfig all Ipconfig Lists all of the commands and their usages available for use A Displays and modifies the IP to Physical address translation tables used by Address Resoluti...

Страница 69: ...mand prompt as instructed Route PRINT will show all active routes on PC Route ADD will add a routing table to network Route DELETE Destination Netmask Gateway Interface will delete the unwanted routin...

Страница 70: ...g 4 24mA 0 2 Accuracy 150 Ohm Impedance Ethernet Port Ethernet Port 10 100baseT RJ45 Connector IEEE 802 3 Auto MDIX Link Activity Link 100baseT via LED Serial Port RS232 DB9 Female DCE RTS CTS DTR DCD...

Страница 71: ...5 CAN IC RSS 119 EU EN300113 2 EN300220 2 AS NZS AS NZS4295 Hazardous Area CSA Class I Div 2 ATEX IEC Ex zone2 Safety UL Listed IEC 60950 RoHS Compliant General Size 186 x 115x 36mm 7 3 4 4 Housing IP...

Страница 72: ...stick Firmware files contact ELPRO Technical Support for these files Ethernet Cable PC for transferring files Preparing the USB memory stick for firmware upgrade Not all USB flash drives are configure...

Страница 73: ...Offset Partition 1 Primary 1911 MB 0 B Partition Type Size Offset Partition 1 Primary 100 MB 64 KB Partition 2 Primary 1810 MB 101 MB 6 DISKPART list disk Disk Status Size Free Dyn Gpt Disk 0 Online 2...

Страница 74: ...the stick from within selected before pressing the Start button Upgrade Procedure 1 Prior to performing the upgrade you will need to copy the supplied firmware files to the USB Stick root directory T...

Страница 75: ...should not have been changed or erased during this process DO NOT remove the Flash drive or interrupt the power to the module while this is happening If the upgrade process is interrupted module could...

Страница 76: ...ore talk method of minimizing but not eliminating collisions caused by simultaneous transmission by multiple radios IEEE 802 11 states collision avoidance method rather than collision detection must b...

Страница 77: ...e of Electrical and Electronics Engineers New York www ieee org A membership organization that includes engineers scientists and students in electronics and allied fields It has more than 300 000 memb...

Страница 78: ...h the proper tools can still figure out an authorized MAC address masquerade as a legitimate address and access a closed network Every wireless 802 11 device has its own specific MAC address hard code...

Страница 79: ...work The first part TCP is the transport part which matches the size of the messages on either end and guarantees that the correct message has been received The IP part is the user s computer address...

Страница 80: ...Offset Detected indication for this 115S module 30001 30008 Offset Inputs AIN 1 AIN8 30017 Offset Modbus Error Counter for this 115S module 30018 Offset Modbus Last Error Code for this 115S module Ap...

Страница 81: ...n of reference number and transfer length is invalid For a controller with 100 registers the PDU addresses the first register as 0 and the last one as 99 If a request is submitted with a starting regi...

Страница 82: ...teway Device Failed to Respond Specialized use in conjunction with gateways Indicates that no response was obtained from the target device Usually means that the device is not present on the network 6...

Страница 83: ...roduced by others will not reflect on the original authors reputations Finally any free program is threatened constantly by software patents We wish to avoid the danger that redistributors of a free p...

Страница 84: ...py of the corresponding source code to be distributed under the terms of Sections 1 and 2 above on a medium customarily used for software interchange or c Accompany it with the information you receive...

Страница 85: ...ase this License incorporates the limitation as if written in the body of this License 9 The Free Software Foundation may publish revised and or new versions of the General Public License from time to...

Отзывы: