![Cooper DTW 200 Скачать руководство пользователя страница 3](http://html1.mh-extra.com/html/cooper/dtw-200/dtw-200_user-manual_2661719003.webp)
CF 139
3
DTW 200/200N (12/10)
8.
Beeper (bp)
After Interval value is entered, bp is displayed and then On. Press UP or DOWN switch to select On. OFF, or
FF, then press PRG to enter.
ON- beeper sounds for Good, NG and capacity overload
OFF- beeper sounds for overload only
FF- beeper sounds for NG and capacity overload
9. Units
(Un)
After the beeper is programmed, UN is displayed, then the current unit selection. Press UP to cycle the units;
lbf-in, ozf-in, kgf-cm, N-m and N-cm.
After the units are entered, -S- is displayed to confirm programming completion and zero is shown.
After High and Low setpoints are set and beeper is set to ON;
In PP mode,
Under LO setpoint - no LED or beep
Over LO setpoint – Green LED lights
Over HI – red LED flashes and beeps sounds
In PD mode, no indicator or beep for values before Peak Down is sensed.
Under LO setpoint - Red LED flashes and slow beep sounds
Between LO and HI – Green LED lights and constant tone sounds
Over HI – Red LED flashes and fast beep sounds
In Real Time and C mode
Under LO setpoint - no LED light or beep
Between LO and HI – Green LED lights and beep sounds
Over HI – Red LED lights and beep sounds
DATA MEMORY
Storing and Recalling Data from Memory
Memory functions work in PP and PD modes. Store up to 800 values in memory.
1. Measure torque in PP or PD mode, when the display resets by either Auto Zero or manually pressing CLR,
the peak value is stored.
2. To recall a value, press MEM and the last stored memory is displayed. Press UP or DOWN to select a
memory location and torque value. The display cycles between location and value.
Clearing Data from Memory
Single clear:
Press MEM, then press UP or DOWN to move to a memory location. When the desired memory
location is displayed, press CLR. Press CLR again to clear the data and ---- is displayed to confirm deletion.
All clear:
Press CLR and hold until the display shows ALL then press CLR again and ---- is displayed to confirm
deletion.
Downloading Memory Data
1. Press ON/OFF to turn on.
2. Press MEM and after memory data is displayed press MEM again and FA is displayed. Press UP or DOWN to
select the first memory location then press MEM and LA is displayed. Use UP or DOWN to select the last
memory location. Press MEM again and the data is sent. While data is output –P- is displayed.
NOTE: by pressing DOWN switch for more than 1 second, the download function can be terminated.
Statistics
Press Statistics and the number of data, Max, Min, and Avg are displayed in sequence.