![Cooper DTW 200 Скачать руководство пользователя страница 1](http://html1.mh-extra.com/html/cooper/dtw-200/dtw-200_user-manual_2661719001.webp)
CF 139
1
DTW 200/200N (12/10)
DIGITAL TORQUE TESTER/WRENCH DTW 200/200N
USER’S GUIDE
LIST OF EQUIPMENT
1. Torque
Tester
2. Stepless CW one-way clutch (included for DTW 200, available for DTW 750)
3. AC
adapter/charger
4. Carrying
case
Read First: Safety Information
For safety, and for damage avoidance, be sure to read this manual thoroughly. The warranty is only valid when the
product is used following the instructions provided within this manual.
•
Do not use tester in high temperature, high humidity, or in damp or wet areas.
•
Recommended operating temperature is between 0-42ºC (32-100ºF).
•
Do not apply torque exceeding the rated capacity (180 lbf-in), regardless of whether the unit is On or Off. Avoid
shock load. Do not use with impact wrenches.
•
When charging the battery, be sure to use the provided AC adapter/charger exclusively.
•
Do not use lacquer thinner or any solvent to clean the unit.
•
Do not disassemble or modify the unit.
1.
ON/OFF Switch
Press once to turn on, press again to turn off. After 10 minutes of non-use, unit will shut off
automatically.
2.
MODE
Select
GO
(Real Time),
PP
(Peak),
PD
(Peak Down),
C
(Continuous Output Mode)
3.
CLEAR
Reset display to zero and send data to memory
4.
LCD Display
Displays torque value, battery icon, mode and units
5.
GO/NG Indicator
Green for values between LO and HI setpoints, flashing red for values above HI, solid green
for data output.
6.
DOWN
Change values or numeric places
7.
UP
Change values or options
8.
PRG
Enter programming mode or enter values
9.
MEM
Display memory locations and data
10.
STAT
Display statistics; number of records, Max, Min, and Ave.
USB Port
Send data to computer via USB cable
Charge light
Lights when charging, off when complete
DC IN
AC Charger /adapter receptacle
Reset