Option
0
Disabled. The display shows alert messages for faults, but does not
sound alert tones.
1
Enabled (default). The display shows alert messages, and the system
gives alert tones.
Command 151 to 158: Plug-by Communicator Outputs
1. Note that All Fault is active for the following faults: AC Fail, Anti-Mask, Aux
DC, Battery Load Test Fail, Battery Missing, Comms Fail, Jamming,
Keypad Ident Fail, Line Fail (internal communicator only), Low Battery, RF
Low Battery, Supervision Fail, Telecommand Low Battery, uCom Fail,
Zone AC Fail, Zone Battery Fault, Zone Fault, Zone Low Battery and Zone
Pwr O/P. (Plug-By/Plug-On fail no longer trigger an All Fault output.)
2. In the event of a mains fail (or if the installer leaves engineering with mains
absent) the control unit waits one minute and then logs an AC Alert, but
does not start any communication. If the mains fail persists, then after a
time of 15-19 min (chosen at random) the control unit logs an AC Fail and
also starts a communication.
If you select a Scandinavian default in Command 0, the control unit waits at
least 60 minutes before reporting.
Printing the Event Log (9853 only)
The following log messages are new in version 5.0x.:
Keypad Display
Printed (9853 only)*
Meaning
AC Alert
Keypad displayed mains fail message
AC Fail
AC Lost
Mains power supply failed
Z== Lock Out
The system locked out the zone when
attempting to rearm at the end of the bell
run time.
Z== Lock Out Rst
The system restored a locked out zone
zone.
4. Changes For the End User
Access Codes
With version 5 access codes can have “0” as the first digit.
The end user no longer has to press
X
to cancel a mistake in entering an
access code, they simply key in the correct code again.
If a user keys in an incorrect code four times, the control unit locks all keypads
for 90 seconds.