24
Reset Only
Users of this type have access to User
options 1 and 2. They can reset 24-hour
alarms from any keypad.
Panic Code
Users of this type have no access to user
menus and cannot set or unset the system.
Entering a user code of this type generates
a Panic Alarm and activates a full alarm
(causing internal and external sounders and
strobe lights to operate).
Z
To set up a Panic code, Duress Allow in
Engineer option 45-24 must be set to
YES.
Duress Code
Users of this type have the same abilities as
a standard global user but, when the user
code is entered, a silent alarm is
generated
1
, which could be sent to an alarm
receiving centre. This enables the user to
appear to operate the alarm system
normally if being coerced.
Z
To set up a Duress code, Duress Allow
in Engineer option 45-24 must be YES.
Access
Users of this type have no access to user
menus and cannot set or unset the system.
Entering a user code of this type temporarily
activates outputs of type "Code Accepted",
Access or "Access Code", which could be
used to operate electric door strikes or
similar mechanisms.
1
Outputs of type "Duress Alarm" are activated if the system is being set. Outputs of type "Duress Alarm" or "Panic
Alarm" are activated if the system is being unset.
Содержание 65EN
Страница 1: ...MANAGER S MANUAL HARDWIRED CONTROL PANELS...
Страница 46: ...46 User Details No Name Type Partitions 1 Manager...
Страница 47: ...47 Zone Details Zone No Location Chime Y N Partitions...
Страница 48: ...48 Telecommand Details Tcmd No Telecommand Name Button Partitions...
Страница 49: ...49 Service Record Date Engineer Action...