2

NOTE:

 Coverplate mounts to recessed mounted 

standard junction boxes (Fig. 2). Junction box must be 

at least 1-1/2 in. in depth for proper installation for  

recessed mount application.

1. 

Install protective reflectors (I) onto lampholders 

by lining up the nipples on the covers, over the 

lampholder slots. Lock into place by twisting 

covers counterclockwise (Fig. 3).

2. 

Line up the holes on the mounting bracket (H) with 

the holes on your junction box. Using either (2) #6 

screws or (2) #8 screws (D) (depending on the  

size of the holes in your junction box), attach the 

mounting bracket (H) to your junction box (Fig. 4).

3. 

Thread fixture wires through coverplate gasket (B).

4. 

Connect copper colored ground wire (coming from 

the fixture coverplate) to the house ground wire  

using wire nut (E) provided. Connect fixture black 

wire to house black wire, fixture white wire to house 

white wire using wire nuts (E) provided (Fig. 5).

5. 

Attach fixture (A) to the mounting bracket (H) using 

the center bolt (G) provided. Be sure no loose wires 

remain sticking out from underneath the coverplate. 

Insert plastic color-matched plug (F) in center bolt 

hole for finished appearance (Fig. 6).

6. 

Apply silicone caulking around edges of coverplate 

 

and in any open holes to provide a watertight seal  

 

from rain and moisture.

7. 

Insert lampholder gaskets (C) into lampholder 

assembly, tightly against lampholder, and screw 

bulbs into each lampholder (Fig. 7). (Do not 

overtighten bulbs.)

8. 

Turn on power at mainfuse/breaker box.

OPERATING YOUR FIXTURE

1.

  Move slide switch on bottom of the sensor to

“TEST”. Set sensitivity slide switch to medium  

or “M” (Fig. 8).

2. 

Turn on the power to fixture. Allow fixture to warm 

up approximately 90 seconds before testing. (Lights 

may or may not come on during warm-up period; 

this is normal.)

3. 

Aim sensor head in desired position.

NOTE:

 Maintain air spacing between lamps and sensor 

head, at least 1 in. Make sure sensor head is positioned 

with control switches facing towards the ground.

4. 

Walk across the detection zone at the farthest 

distance you wish your detector to detect motion.

5. 

Adjust sensitivity until you get desired results. 

For more range, aim sensor head slightly upwards. 

For less range, aim sensor head slightly downward.

6. 

Move slide switch to 4 min or 12 min (AUTO mode), 

or to one of the three “Night Time On” settings. At 

dusk, lights will operate in the “AUTO” or “Night 

Time On” settings.

 

Mode of 

MODE Knob 

How to Set

 

Operation 

Adjustment 

Power Switch

Test Setting

Lights should turn ON with

motion both day and night.

Lights should turn OFF

after 4 seconds.

Keep the power 

to the fixture ON.

TEST

Motion Activated

(“Auto” Setting)

Lights should turn ON with

motion only at night and should 

turn off after 4 or 12 min.

of no motion.

AUTO 4 MIN

or

AUTO 12 MIN

Keep the power 

to the fixture ON.

Dusk-to-Dawn Setting

Override Mode

(activated only at night)

Lights should stay ON 100% 

brightness from dusk to dawn and 

then reset to the “AUTO” or “Night 

Time On” setting at next dawn.

AUTO 4 MIN

or

AUTO 12 MIN

or

ALL “NIGHT TIME ON” MODES

Turn the power 

OFF-ON-OFF-ON

within 3 seconds.

Fig. 2

Octagonal

Round

1-1/2 in.

ENERGY STAR

®

To meet ENERGY STAR

®

 requirements, the photosensor control knob must be in the 

“Auto” mode to prevent operation during full daylight. Maximum lamp wattage can not 

exceed 250 watts.

SELECTING YOUR DESIRED FEATURE

Return to “Auto” 

or “Night Time On” Settings

 (motion activated)

from any of the above settings.

AUTO 4 MIN

or

AUTO 12 MIN

or

ALL “NIGHT TIME ON” MODES

Turn the power OFF

for at least 90 seconds

and then back ON.

Continuous Override Mode

(Standard Floodlight Setting)

Lights should stay ON 

continuously both day and night 

(must be reset manually).

TEST

Turn the power 

OFF-ON-OFF-ON

within 3 seconds.

ENERGY STAR

®

 is sponsored by the U.S.

Environmental Protection Agency & U.S.

Department of Energy.

Visit www.energystar.gov to learn more.

D

H

D

Fig. 4

2 Hour 

NIGHT TIME ON

then Motion Activated

Lights should turn ON 

automatically at night 100% 

brightnes for 2 hours, then reset 

to regular auto motion settings for 

the remainder of the evening.

NIGHT TIME ON

2 HR

(2 Hours)

Note:

 Once the light has come 

ON in the selected “Night Time 

On” mode, you cannot change 

the mode setting until the next 

dawn. The light will operate in 

the first “Night Time On” mode 

selected (2 hour, 4 hour, 6 hour) 

even if changed.

Keep the power 

to the fixture ON.

4 Hour 

NIGHT TIME ON

then Motion Activated

Lights should turn ON 

automatically at night 100% 

brightnes for 4 hours, then reset 

to regular auto motion settings for 

the remainder of the evening.

NIGHT TIME ON

4 HR

(4 Hours)

Note:

 Once the light has come 

ON in the selected “Night Time 

On” mode, you cannot change 

the mode setting until the next 

dawn. The light will operate in 

the first “Night Time On” mode 

selected (2 hour, 4 hour, 6 hour) 

even if changed.

Keep the power 

to the fixture ON.

6 Hour 

NIGHT TIME ON

then Motion Activated

Lights should turn ON 

automatically at night 100% 

brightnes for 6 hours, then reset 

to regular auto motion settings for 

the remainder of the evening.

NIGHT TIME ON

6 HR

(6 Hours)

Note:

 Once the light has come 

ON in the selected “Night Time 

On” mode, you cannot change 

the mode setting until the next 

dawn. The light will operate in 

the first “Night Time On” mode 

selected (2 hour, 4 hour, 6 hour) 

even if changed.

Keep the power 

to the fixture ON.

Fig. 6

F

G

A

Fig. 5

Wall mount

Eave mount

B

A

A

E

E

E

Fig. 3

I

A

Fig. 7

C

C

Fig. 8

 

MODE

TEST

4 MIN

12 MIN

2 HR

4 HR

6 HR

SENSITIVITY

H

M

L

AUTO

NIGHT TIME ON

1-1/2 in.