MPWA

Fe a t u r e s ,   C a t a l o g   L o g i c  

a n d   O p t i o n s

The MPWA features a reflector
system in the lower optical
compartment that facilitates two
tasks-reading and patient
examination. 

The MPWA is used for obtaining
maximum efficiency while
providing cut off and glare control
to the remaining of the room’s
surroundings.  With the push of a
switch, the upper lamp of the
lower compartment can be
energized to aid in evaluation of
the patient.  The reflector works
with this lamp by providing
maximum output and control of
light over the patient’s torso for
examination or any other tasks
that may be necessary.  The
effectiveness of this lamp/optical
system is maximized by its
flexibility in utilizing these two
lamps in conjunction or
separately.  

B a l l a s t s

Fixtures are supplied standard
with electronic ballasts.
Magnetic, energy saving ballasts
are available with T8 lamps only
(LEOC8).  An optional radio
interference filter (RIF) is
commonly used with magnetic
ballasts to reduce radio
interference with sensitive
equipment.   

C i r c u i t r y

All individual input circuits will be
supplied with a quick disconnect
module (QDM) to facilitate ease of
maintenance and installation.

GCO

(grounded convenience

outlet) and 

FNL 

(fluorescent night

light) options are commonly run
on separate circuits. Each will be
supplied with a QDM, separate
from the primary lamp sources
and will require additional
switching and wiring by others.
All primary lamp sources are
wired onto the same circuit unless
specified otherwise (See
Switching Controls).  

E x a m   L i g h t

EXL Feature-

This standard feature

includes a specular reflector that
separates the two lower lamps.
The upper lamp in the lower
compartment is for use as an
exam light.  The lower lamp in the
same compartment is intended for
reading and other ordinary tasks.
(The upper lamp in the lower
compartment is switched
independently of the primary
lamp system via a rocker switch;
add "R" for installation on right
side of unit, 

EXLR; 

add "L" for

installation on left side of unit,

EXLL

).  

S w i t c h i n g   C o n t r o l s

No switching option specified

implies the fixture will ship with

input leads left unwired for switch

wiring to be completed in field as

desired. 

PS4-

4-position pull chain

switching. All primary lamps

(except EXL lamp) wired in

sequence by following: lower

lamps on, upper lamps on, all

lamps on, all lamps off.  (120V

only, brushed nickel finish,

installed in center of unit on

bottom of power tray).  

PS1D-

2 position pull chain switch,

controls the bottom lamp

compartment only (except EXL

lamp).  (120V only, brushed nickel

finish, installed in center of unit

on bottom of power tray).  Upper

lamp compartment is on a

separate circuit to be wired and

switched at wall or as desired.

LVCP-

Low voltage controller,

patient controlled.  Mounted

inside unit for patient control of

all primary lamps-upper and

lower lamp compartments. Wired

in sequence for lower lamp on

(except EXL lamp), upper lamps

on, all lamps on, all lamps off.

Includes 1/4" phone jack type

receptacle centered in bottom of

wire way for input control by

others or may be used with

accessory 

MBC

-momentary

button cord switch (See

accessories).  

LVCF-

Low voltage controller,

facility controlled.  Mounted

inside unit, controller is left

unwired for specific wiring/control

requirements of facility.  Includes

1/4" phone jack type receptacle,

centered in bottom of wire way

for input control by others or may

be used with accessory 

MBC-

momentary button cord switch

(See accessories).  

O t h e r   O p t i o n s

EBP-

The emergency battery pack

option is a good candidate for
facilities that do not have
emergency generator systems.
Test switch and indicator light will
be installed on top of unit in
middle of the power tray.  

FNL- 

Fluorescent night-light, 2-pin

(G23 Base), 7 or 9w twin tube
lamp installed in center of upper
compartment of fixture, uses a
magnetic ballast. FNL is wired on
a separate circuit.   (Lamps by
others). 

GCO-

Grounded convenience

outlet. White in color on units
with white finish; black in color on
all other finish options, wired on a
separate circuit.  (120V only,
maximum 10 amps, installed on
bottom right side facing unit; add
"L" for installation on left side of
unit, 

GCOL

).  

GLR-

Fuse and holder, wired to

primary lamp circuit only.    

NRL-

White LED nurses chart

reading light.  Directed so as not
to discomfort the patient.
Switched separately via rocker
switch, both lamp and switch
located on the bottom of the
power tray.  White in color on
units with white finish; black in
color on all other finish options
(120V only, installed on either the
right or left side, facing unit; add
"R" for installation on right side of
unit, 

NRLR

; add "L" for installation

on left side of 
unit, 

NRLL

).  

RIF-

Radio interference filter, for

use with magnetic T8 ballast only.
(1 per ballast).  

SF1-

Tamper-proof Torx™-head

fasteners

Ac c e s s o ri e s

MBC-

Momentary button cord

switch. May be used with LVCP or
LVCF options to control lamps.  All
units are wired at factory as
specified per catalog logic (See
Switching Controls).  

VRSD-

Torx™-head tamper-proof

screwdriver (for use with SF1
option)

M a i n t e n a n c e

The MPWA is designed to
facilitate ease of maintenance.  
Its three part assembly makes for
efficient installation.  No tools are
required for relamping or
substituting electrical power trays
on standard fixtures. When
maintenance is required, simply
loosen the two end thumbscrews
and slide the partial clamshell,
front lens assembly forward and
off.  The lamps and power tray
will now be accessible and can be
removed by  quarter-turn
fasteners.  This assembly hangs
suspended on the back pan while
it is easily disconnected via a
quick disconnect power
connector.  Spare units can speed
the maintenance process by easily
substituting the power tray, thus
causing less disruption in the
room.