Cooper Lighting METALUX VT2 Скачать руководство пользователя страница 2

Metalux • Customer First Center • 1121 Highway 74 South • Peachtree City, GA 30269 • TEL 770.486.4800 • FAX 770.486.4801

09/29/2008 10:06:07 AM

Specifications and Dimensions subject to change without notice.

ADF071394

PHOTOMETRICS

ORDERING INFORMATION

ACCESSORIES

SHIPPING DATA

VT2

C o e ffi c i e n t s   o f   U t i l i z a t i o n

Effective floor cavity reflectance

20%

rc

80%

70%

50%

30%

10%

0%

rw

70 50 30 10

70 50 30 10

50 30 10

50 30 10

50 30 10

0

RCR

0
1
2
3
4
5
6
7
8
9

10

L u m i n a n c e   Da t a

Average

Average

Average

Angle

0-Deg

45-Deg

90-Deg

in Deg

cd/sm

cd/sm

cd/sm

45

7779

10632

11288

55

7074

10221

10954

65

6110

9764

12196

75

5205

13928

20408

85

4251

27797

39527

Z o n a l   L u m e n   S u m m a r y

Zone

Lumens

%Lamp

%Fixture

0-30
0-40
0-60
0-90
0-180

||

?

C a n d l e p o we r

Angle

Along II

45°

Across

?

0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90

VT2-254DR-UNV-
EB81-WL-M4-U
Electronic Ballast
(2) F54/T5/835 Lamps
4460 Lumens each
Spacing criterion:
(II) 1.2 x mounting
height, (

?

) 1.6 x

mounting height
Efficiency 74.3%
Test Report: 
127P111
LER = FI57
Yearly Cost of 1000
lumens, 3000 hrs at
.08 KWH = $4.24

1615 

1615 

1615

1613 

1632 

1648

1592 

1673 

1723

1556 

1704 

1781

1504 

1717 

1820

1438 

1712 

1839

1357 

1683 

1815

1262 

1625 

1743

1154 

1532 

1635

1033 

1412 

1499

902 

1263 

1355

762 

1101 

1180

621 

944 

994

485 

775 

968

362 

667 

1051

253 

677 

992

158 

612 

827

74 

455 

647

26 

297 

463

87  87  87  87 

85  85  85  85 

80  80  80 

76  76  76 

72  72  72 

70

78  73  70  66 

75  71  68  65 

67  64  62 

64  61  59 

60  59  57 

55

70  63  57  52 

68  61  56  51 

58  53  50 

55  51  48 

52  49  46 

44

64  55  48  43 

61  53  47  42 

51  45  41 

48  43  40 

45  42  39 

37

58  48  41  36 

56  47  40  35 

45  39  34 

42  38  34 

40  36  33 

31

53  43  36  31 

51  42  35  30 

40  34  30 

38  33  29 

36  32  28 

26

49  39  32  27 

47  38  31  26 

36  30  26 

34  29  25 

33  28  25 

23

45  35  28  23 

44  34  28  23 

32  27  23 

31  26 22 

30  25  22 

20

42  32  25  21 

41  31  25  20 

30  24  20 

28  23  20 

27  23  19 

18

39  29  23  18 

38  28  22  18 

27  22  18 

26  21  18 

25  21  17 

16

37  27  21  17 

36  26  20  16 

25  20  16 

24  19  16 

23  19  16 

14

1411

15.8

21.3

2397

26.9

36.2

4380

49.1

66.2

6268

70.3

94.8

6614

74.2

100.0

C o e ffi c i e n t s   o f   U t i l i z a t i o n

Effective floor cavity reflectance

20%

rc

80%

70%

50%

30%

10%

0%

rw

70 50 30 10

70 50 30 10

50 30 10

50 30 10

50 30 10

0

RCR

0
1
2
3
4
5
6
7
8
9

10

L u m i n a n c e   Da t a

Average

Average

Average

Angle

0-Deg

45-Deg

90-Deg

in Deg

cd/sm

cd/sm

cd/sm

45

4874

6095

5343

55

4392

5171

4906

65

3669

4791

5995

75

2853

5921

5721

85

1868

5874

5512

Z o n a l   L u m e n   S u m m a r y

Zone

Lumens

%Lamp

%Fixture

0-30
0-40
0-60
0-90
0-180

||

?

C a n d l e p o we r

Angle

Along 

II

45°

Across

?

0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90

VT2-232DR-UNV-
EB81-WL-M4-U

Electronic Ballast
(2) T8 Lamps
2850 Lumens each
Spacing criterion:
(II) 1.3 x mounting
height, (

?

) 1.6 x

mounting height
Efficiency 81.7%
Test Report: 
127P113
LER = FI71
Yearly Cost of 1000
lumens, 3000 hrs at
.08 KWH = $3.39

1036 

1036 

1036

1036 

1059 

1077

1023 

1114 

1175

1000 

1175 

1275

968 

1227 

1344

926 

1255 

1352

876 

1245 

1284

817 

1184 

1182

750 

1080 

1070

674 

961 

946

591 

834 

833

501 

706 

780

408 

597 

785

317 

533 

816

233 

520 

755

160 

489 

624

97 

396 

518

45 

302 

434

16 

224 

353

96  96  96  96 

93  93 93 93

87 87 87

82 82 82

78 78  78 

76

86  81  77  73 

83  78  74  71 

74  70  68 

69  67  64 

65  63  61 

59

77  69  63  58 

74  67  61  57 

63  58  54 

60  56  52 

56  53  50 

48

70  60  53  47 

67  59  52  46 

55  49  45 

52  47  43 

49  45  42 

40

64  53  45  40 

61  52  44  39 

49  43  38 

46  41  37 

44  39  35 

33

58  47  39  34 

56  46  39  33 

44  37  32 

41  36  31 

39  34  31 

29

54  42  35  29 

52  41  34  29 

39  33  28 

37  32  27 

35  30  27 

25

50  38  31  26 

48  37  30  25 

35  29  25 

34  28  24 

32  27  24 

22

46  35  28  23 

45  34  27  22 

32  26  22 

31  25  21 

29  25  21 

19

43  32  25  20 

42  31  25  20 

30  24  20 

28  23  19 

27  22  19 

17

40  29  23  18 

39  29  22  18 

27  22  18 

26  21  17 

25  20  17 

15

985

17.3

21.1

1675

29.4

36.0

2999

52.6

64.4

4316

75.7

92.7

4658

81.7

100.0

Width
Blank

=4' Length 

8T

=8' Length

Series

VT2

=Vapor-Tite

Number of Lamps

(3)

1

=1 lamp (T5 or T8)

2

=2 lamps (T5 or T8)

3

=3 lamps (T8 only)

(Lamps not included)

Lamp Type

32

=32W T8 Lamp (4' Long)

54T5

=54W T5HO Lamp (4' Long)

Lens
DR

=Internal Prismatic Lens/15% DR High Impact Additive (Standard)

DR-100%

=100% High Impact Additive

LEX

=High Impact Clear Polycarbonate LEXAN Lens/Low Brightness Pattern

Voltage 

(1)

120V

=120 Volt

277V

=277 Volt

347V

=347 Volt

480V

=480 Volt

UNV

=Universal

Voltage 120/277V

UNC

=Universal

Voltage 347/480V

(T5 Linear Only)

Fusing
GL

=Single Element Fuse

GM

=Double Element Fuse

Emergency

=EM Installed,

see EM options table

(3) (4)

NOTES:

(1)

Ballast type used only if ballast & voltage is chosen 

(2)

Not available when specify-

ing emergencies, voltage must be specific. 

(3)

T5HO is only available in 1 or 2-lamp versions

only.

(4)

Emergency option in 3 lamp version must use remote mount test switch.

Options
RIF1

=Radio 

Interference Suppressor

TH

=(2) Top Watertite Hubs

TEH

=(2) Top & (2) End  Watertite

Hubs (all Watertite Hubs have 1/2" 
Conduit Entry)

TILW

=Tandem In-Line Wiring

Option (Consult TILW Option Catalog Page)

PI/CPI

=Plug-In Option

DD

=Deep Diffuser (4' Length)

M4

=Specular Reflector

SSL

=Stainless Steel Latches

Packaging
U

=Unit Pack

PALC

=Job

Pack in Carton

Ballast Type

(1)

T8 Systems
EB8

=T8 Electronic Instant Start.

(4)

Total Harmonic  Distortion < 20%

EB8 /PLUS

=T8 Electronic Instant Start.

High Ballast Factor >1.13. Total 

Harmonic  Distortion < 20%

ER8

=T8 Electronic Program Rapid Start.

Total Harmonic Distortion < 10%

ER8 /PLUS

=T8 Electronic Program Start.

High Ballast Factor >1.13. Total 

Harmonic Distortion < 10%

EB8 /L

= T8 Electronic Instant Start w/0.80 

Ballast Factor.

T5 Systems
EBT

=T5HO Electronic Program Start.

No. of Ballast

1 or 2

No. of 

Ballast

1 or 2

No. of Ballast

1 or 2

No. of Ballast

1 or 2

No. of Ballast

1 or 2

WL

=Wet

Location 

Label

(Available for 4' Fixture Length) To Complement 
Deep Diffuser Depth of 8' Fixture

No. of 

Ballast

1 or 2

S A M P L E   N U M B E R : 8 T V T 2 - 2 5 4 D R - U N V- E B 8 2 - M 4 - U

Accessories

(order separately)

VT2-Chain/Set-U

=Chain Hanging Set

Includes 6 ft. of chain, 4 large 
S-Hooks and 4 small S-Hooks
Order One (1) Kit for each 
2' or 4' Fixture
Two (2) Kits Recommended 
For 8' Fixture

VT2-SS-MBK

=Stainless 

Steel Mounting Bracket

VT2-132DR-WL

35 lbs.

VT2-232DR-WL

35 lbs. 

Catalog No.

Wt.

Отзывы: