Cooper Lighting Metalux 232T8 Скачать руководство пользователя страница 2

Metalux • Customer First Center • 1121 Highway 74 South • Peachtree City, GA 30269 • TEL 770.486.4800 • FAX 770.486.4801

07/08/2008 2:19:55 PM

Specifications and Dimensions subject to change without notice.

ADF051819

PHOTOMETRICS

ORDERING INFORMATION

2AC2

C o e ff

i

c i e nt s of U t i l i z a t i on

Effective floor cavity reflectance

20%

rc

80%

70%

50%

30%

1

0%

0%

rw

70 50 30

1

0

70 50 30

1

0

50 30

1

0

50 30

1

0

50 30

1

0

0

R

CR

0
1
2
3
4
5
6
7
8
9

1

0

L u m i n a n c e Da t a

Average

Average

Average

Angle

0-Deg

45-Deg

90-Deg

in Deg

cd/sm

cd/sm

cd/sm

45

1666

1624

2047

55

1355

1514

1938

65

1052

1151

1257

75

956

935

1056

85

811

764

811

Zo n a l L u m e n S u m m a r y

Zone

Lumens

%Lamp

%Fixture

0-30
0-40
0-60
0-90
0-1

80

Angle

Along II

45°

Across

0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90

2AC2-228T5-BP

Electronic Ballast
(2) F 28T5 L amps
2900 Lumens each
Spacing criterion:
(II) 1.1 x mounting

height, ( ) 1.1 x
mounting height
Efficiency 66.8%
Test Report:
2AC2-228T5PBW.IES
LER = FL67
Yearly Cost of 1000
lumens, 3000 hrs at

.08 KWH = $3.59

1712

1712

1712

1699

1705

1710

1651

1675

1697

1573

1623

1662

1481

1542

1562

1377

1425

1409

1262

1274

1250

1137

1112

1162

1005

955

1112

867

845

1065

724

746

996

572

639

818

419

511

523

327

358

391

252

252

304

182

178

201

115

110

117

52

49

52

0

0

0

79 79 79 79

78 78 78 78

74 74 74

71 71 71

68 68 68

67

73 70 68 65

71 69 66 64

66 64 62

63 62 60

61 60 59

57

67 62 58 54

65 61 57 54

58 55 52

56 54 51

54 52 50

49

62 55 50 46

60 54 49 45

52 48 45

50 47 44

49 46 43

42

57 49 44 39

55 48 43 39

47 42 39

45 41 38

44 40 38

36

52 44 38 34

51 43 38 34

42 37 34

41 37 33

40 36 33

32

49 40 34 30

47 39 34 30

38 33 30

37 33 30

36 32 29

28

45 36 31 27

44 36 31 27

35 30 27

34 30 26

33 29 26

25

42 33 28 24

41 33 28 24

32 27 24

31 27 24

31 27 24

22

39 31 25 22

38 30 25 22

30 25 22

29 25 22

28 24 22

20

37 28 23 20

36 28 23 20

28 23 20

27 23 20

26 22 20

19

1267

21.8

32.7

1978

34.1

51.1

3270

56.4

84.4

3873

66.8

100.0

3873

66.8

100.0

C o e ff i c i e n t s o f Ut i l i z a t i o n

Effective floor cavity reflectance

20%

rc

80%

70%

50%

30%

1

0%

0%

rw

70 50 30

1

0

70 50 30 10

50 30

1

0

50 30

1

0

50 30

1

0

0

R

CR

0
1
2
3
4
5
6
7
8
9

1

0

L u m i n a n c e Da t a

Average

Average

Averag

e

Angle

0-Deg

45-Deg

90-Deg

in Deg

cd/sm

cd/sm

cd/sm

45

1611

1655

2028

55

1322

1502

1893

65

1036

1148

1299

75

940

924

1045

85

780

749

795

Z on a l L u m e n S u m m a r y

Zone

Lumens

%Lamp

%Fixture

0-30
0-40
0-60
0-90
0-1

80

Angle

Along II

45°

Across

0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90

2AC2-232-BI

Electronic Ballast
(2) F3 2T8 L amps
3000 Lumens each
Spacing criterion:
(II) 1.1 x mounting

height, ( ) 1.2 x
mounting height
Efficiency 63.6%
Test Report:
2AC2-232PBW.IES
LER = FL58
Yearly Cost of 1000
lumens, 3000 hrs at

.08 KWH = $4.15

1650

1650

1650

1637

1643

1646

1590

1613

1631

1516

1558

1590

1426

1475

1506

1325

1366

1404

1215

1242

1300

1095

1113

1200

970

986

1116

838

861

1055

703

745

966

558

634

799

412

503

592

322

357

404

249

249

292

179

176

199

113

110

118

50

48

51

0

0

0

76 76 76 76

74 74 74 74

71 71 71

68 68 68

65 65 65

64

70 67 64 62

68 65 63 61

63 61 59

60 59 57

58 57 56

54

64 59 55 52

62 58 54 51

56 52 50

54 51 49

52 49 48

46

59 52 47 43

57 51 47 43

49 46 42

48 44 42

46 43 41

40

54 47 41 37

52 46 41 37

44 40 37

43 39 36

41 38 36

34

50 42 36 32

48 41 36 32

40 35 32

39 35 32

38 34 31

30

46 38 32 29

45 37 32 28

36 32 28

35 31 28

34 31 28

26

43 35 29 25

42 34 29 25

33 28 25

32 28 25

31 28 25

24

40 32 26 23

39 31 26 23

30 26 23

30 25 22

29 25 22

21

37 29 24 21

37 29 24 21

28 24 21

27 23 20

27 23 20

19

35 27 22 19

34 27 22 19

26 22 19

25 21 19

25 21 19

17

1224

20.4

32.1

1933

32.2

50.6

3212

53.5

84.1

3818

63.6

100.0

3818

63.6

100.0

Candlepower

Candlepower

S A M P L E   N U M B E R :  2 AC 2 - 2 2 8 T 5 - U N V- E B T 1- . 9 0 - U

Number

of Lamps

(Not included)

2=2 Lamp

Wattage (Length)
28T5
=28W T5 (48")
54T5=54W T5HO (48")
32=32W T8 (48")

Voltage

(1)

UNV=Universal

Voltage 120-277

Series

AC2=Accord II Series

Options
GL
=Single Element Fuse
GM=Double Element Fuse
Lamps=Lamps installed
Flex=Flex Installed
EL=Emergency Installed

Packaging
U
=Unit Pack

PALC=Job Pack,

in carton

Width
=2' Width

Shielding

BP=Frosted Lens & White

Baffle
BI=Frosted Lens & Semi-
Specular Baffle

Ballast Type
EB8   
=T8 Electronic Instant Start. 

Total Harmonic  Distortion < 20%

EB8   /PLUS=T8 Electronic Instant Start. 

High Ballast Factor >1.13. Total 

Harmonic  Distortion < 20%

ER8   =T8 Electronic Program Rapid Start. 

Total Harmonic Distortion < 10%

EBT                       =T5 Linear Electronic 

Program Rapid Start 

Total Harmonic 

Distortion < 10%

No. of Ballast

1 or 2

No. of 

Ballast

1 or 2

No. of Ballast

1 or 2

No. of Ballast

1 or 2

Ballast Factor/Type

(For 28W T5 Lamp Only)

N=Normal Light Output .90 BF

(2)

H=High Light Output 1.15 BF

(2)

NDIM=Normal .9 BF Step Dimming

(3)

HDIM=High 1.15 BF Step Dimming

(3)

NOTES: 

(1)

Products also available in non-US voltages and frequencies for international markets. 

(2)

Step Dimming

ballast available for 28W T5 lamps only. 

(3)

.90 and 1.15 ballast factor available for 28W T5 lamps only.

For complete product data, reference the Fluorescent Specification binder. Specifications & dimensions subject to
change without notice. Consult your Cooper Lighting Representative for availability and ordering information.

2AC2-228T5

31 lbs.

2AC2-254T5

31 lbs.

2AC2-232

31 lbs.

S H I P P I N G I N F O R M AT I O N

Catalog No.

Wt.

Отзывы: