P H O T O M E T R I C S

P7-M42T-E7TC

Test No.

H35091

Lamp:

42W PLT

Lumens:

3200

Cutoff:

50°

Spacing:

1.0

Efficiency:

44.8%

Unit LPW:

27.0

Unit Number: P 7 - M 4 2 T- E 7 T _

P 7 - M 3 2 T- E 7 T _

C a n d e l a s

Vertical

CD

Angle

90

0

85

0

75

0

65

0

55

1

45

142

35

594

25

947

15

1313

5

1397

0

1279

L u m i n a n c e

Degree

cd/m

2

85

˚

0

75

˚

0

65

˚

0

55

˚

76

45

˚

8768

4'6"

5'6"

6'6"

8'0"

10'0"

12'0"

4'6"

5'6"

6'6"

8'0"

10'0"

12'0"

63

42

30

20

13

9

C o n e   o f   L i g h t

Distance to

Initial Nadir

Beam

Illuminated Plane

Footcandles

Diameter

Notes and Formulas:

Luminance: To convert cd/m

2

to footlamberts, multiply by 0.2919

Cone of Light:
• Beam diameter is to 50% of maximum footcandles, rounded to the nearest half-foot.
• Footcandle values are initial. Apply appropriate light loss factors where necessary. 

See page 64-65 of catalog.

CU Notes/Formulas:
• maintained illuminance=lamp lumens x CU x light loss factors

room area

• total number of luminaires=total room area x maintained illuminance

lamp lumens x CU x light loss factors

• CU data based on 20% effective floor cavity reflectance.

80%

70%

50%

30%

0%

70

50

30

10

50

10

50

10

50

10

0

53

53

53

53

52

52

50

50

48

48

45

50

48

47

45

47

44

45

43

43

42

40

47

45

43

41

44

40

42

39

41

39

37

45

42

39

37

41

37

40

36

39

36

35

43

39

36

34

38

34

37

34

37

33

32

40

36

34

32

36

31

35

31

34

31

30]

38

34

31

29

34

29

33

29

32

29

28

36

32

29

27

32

27

31

27

31

27

26

34

30

27

25

30

25

29

25

29

25

24

33

28

25

24

28

23

27

23

27

23

23

31

26

24

22

26

22

26

22

26

22

21

Ceiling Reflectance

Wall Reflectance

Room Cavity Ratio

0

1

2

3

4

5

6

7

8

9

10

C o e f f i c i e n t   o f   U t i l i z a t i o n

Z o n a l   L u m e n   S u m m a r y

Zone

Lumens

%Lamp

%Luminaire

0-30

933

29.2

65.1

0-40

1299

40.6

90.6

0-60

1433

44.8

100.0

0-90

1433

44.8

100.0

90-180

0

0.0

0.0

0-180

1433

44.8

100.0

D i s t r i b u t i o n

P7-M32T-E7TC 

Test No.

H35094

Lamp:

32W PLT

Lumens:

2400

Cutoff:

50°

Spacing:

0.9

Efficiency:

43.4%

Unit LPW:

28.9

C a n d e l a s

Vertical

CD

Angle

90

0

85

0

75

0

65

0

55

1

45

75

35

371

25

701

15

1083

5

1159

0

1083

L u m i n a n c e

Degree

cd/m

2

85

˚

0

75

˚

0

65

˚

0

55

˚

76

45

˚

4631

4'6"

5'6"

6'6"

8'0"

10'0"

12'0"

4'0"

5'0"

6'0"

7'6"

9'0"

11'0"

54

36

26

17

11

8

C o n e   o f   L i g h t

Distance to

Initial Nadir

Beam

Illuminated Plane

Footcandles

Diameter

80%

70%

50%

30%

0%

70

50

30

10

50

10

50

10

50

10

0

52

52

52

52

50

50

48

48

46

46

43

48

46

45

43

45

43

44

41

42

40

38

46

43

41

39

42

39

41

38

40

37

36

44

40

38

36

40

36

39

35

38

35

33

41

38

35

33

37

33

36

33

36

32

31

39

35

33

31

35

31

34

30

34

30

29

37

33

31

29

33

29

32

28

32

28

27

35

31

29

27

31

27

30

26

30

26

26

34

29

27

25

29

25

29

25

28

25

24

32

28

25

23

27

23

27

23

27

23

22

30

26

24

22

26

22

26

22

25

22

21

Ceiling Reflectance

Wall Reflectance

Room Cavity Ratio

0

1

2

3

4

5

6

7

8

9

10

C o e f f i c i e n t   o f   U t i l i z a t i o n

Z o n a l   L u m e n   S u m m a r y

Zone

Lumens

%Lamp

%Luminaire

0-30

733

30.5

70.4

0-40

964

40.2

92.6

0-60

1041

43.4

100.0

0-90

1041

43.4

100.0

90-180

0

0.0

0.0

0-180

1041

43.4

100.0

D i s t r i b u t i o n

Note: Specifications and Dimensions subject to change without notice.

Visit our web site at www.cooperlighting.com

Customer First Center  1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770 486.4801 ADI030703

Cooper Lighting  5925 McLaughlin Rd. Mississauga, Ontario, Canada L5R 1B8 905.507.4000 FAX 905.568.7049