IMI-572    AVU040062

Ascent/Strut Fixtures

Sheet 5 of 5

4/26/04         IMI-572

INSTALLATION INSTRUCTIONS

IMPORTANT: READ CAREFULLY BEFORE INSTALLING FIXTURE. 

TM

WARNING: 

Risk of Electric Shock. Disconnect power at fuse or circuit breaker before installing
or servicing.

NEMA TWIST LOCK PHOTOCONTROL & RECEPTACLE:

The photocontrol receptacle is factory installed and ordered with
the fixture. The photocontrol is ordered separately and must be
field installed. The voltage of the photocontrol must match the
voltage of the fixture.

FUSING:

Single fuse is available for use with 120V, 277V or 347V fixture.
Double fuse is available for use with 208V, 240V or 480V fixtures.

MAINTENANCE:

When maintenance is performed, check torque on all fasteners
and tighten to specified torque if required.

CLEANING:

The reflector and door glass may be cleaned with any suitable,
non-abrasive glass cleaning solution, soap or 
detergent and rinsed with clean water. Please remove the 
reflector and door from the fixture prior to cleaning.

KEEP THIS DOCUMENT FOR FUTURE REFERENCE

12.

To remove the REFLECTOR, disconnect the REFLECTOR 
CONNECTOR from the HOUSING. (Fig. 12)

13.

To reinstall, reverse steps 12 and 11, listening for audible 
clicks as REFLECTOR TABS engage REFLECTOR.

NOTE:

This fixture is to be installed as a DOWNLIGHT ONLY. 

This fixture is not suitable for UPLIGHT mounting 
configurations.

REFLECTOR

CONNECTOR

Fig. 12

WARNING: 

Risk of Personal Injury. Fixture may become damaged and/or unstable if not installed properly.
Tighten all fixture components to their recommended torque values.

Содержание INVUE IMI-572

Страница 1: ...ral Upon receipt of fixture thoroughly inspect for any freight damage which should be brought to the attention of the delivery carrier Compare the catalog description listed on the packing slip with the fixture label on the housing to assure you have received the correct merchandise Safety This fixture must be wired in accordance with the national electrical code and applicable local codes and ord...

Страница 2: ...pplied and secure GASKET and WALL PLATE to wall with 4 1 2 13 X 1 12 long BOLTS and 4 Lockwashers Fig 5 Torque BOLTS to 450 in lbs NOTE The SPACER WALL BRACKET and associated components and hardware are shipped separately from the fixture 6 Assemble WALL BRACKET to SPACER and HOUSING with 2 BOLTS 2 FLAT WASHERS and 2 LOCK WASHERS by feeding BOLTS through holes in SPACER and into tapped holes in WA...

Страница 3: ...fuse or circuit breaker before installing or servicing 7 Hook WALL BRACKET over WALL PLATE and place SUPPORT BRACKET into SUPPORT HOLES in WALL PLATE to support fixture as shown Fig 7 Make wire connections in WALL BRACKET Wire the fixture ground lead to the supply ground lead Wire the fixture voltage lead to the supply voltage lead Wire the fixture common lead to the supply common lead NOTE To wir...

Страница 4: ...ll lamp Reinstall DOOR at 20 30 angle to housing ensuring both hinges are engaged Close DOOR ensuring DOOR LATCHES are completely engaged Listen for both cams to click on each latch Fig 9 NOTE Prior to installing the lamp check to make sure lamp is of proper type and wattage Observe lamp manufacturer s recommendations and restrictions regarding lamp operation NOTE Reflector are marked to insure re...

Страница 5: ...age of the photocontrol must match the voltage of the fixture FUSING Single fuse is available for use with 120V 277V or 347V fixture Double fuse is available for use with 208V 240V or 480V fixtures MAINTENANCE When maintenance is performed check torque on all fasteners and tighten to specified torque if required CLEANING The reflector and door glass may be cleaned with any suitable non abrasive gl...

Отзывы: