2. 

Remove the plug-in starter from the receptacle and replace. 

FIG. 6

3. 

Assure that the thumbscrews on the powertray and both latches
on the door are fastened securely.

OPTIC DISTRIBUTION AND ORIENTATION

The Talon Large fixture is offered with some optics that have 
directional distributions. For aiming purposes, the Talon Large was
designed with the flexibility to allow each of its optics to be rotated
to any of four (4) positions, located at 90° increments. There are
two (2) mounting configurations that are used to mount all of the
Talon Large optics. The horizontally-lamped optics (as well as the
Type 4 vertical optic) use the horizontal optics adapter. All vertically
lamped optics use the vertical mount adapter.

1. Vertical Optics

: Open the door and remove the lamp. Use a

screwdriver to slightly loosen (do not remove) the four (4) screws
as shown in 

FIG. 7.

The optic has four (4) keyhole details that

allow it to release by turning the reflector clockwise a few
degrees allowing the optic to be removed. Reposition the optic
and tighten the screws securely.

2. Horizontal Optics

: (this also covers the Type 4 vertical optic).

Open the door and remove the lamp. Use a screwdriver to
remove the four (4) screws as shown in 

FIG. 8

. Reposition the

optic and reinsert the screws securely.

These instructions do not claim to cover all details or variations in
the equipment, procedure, or process described, nor to provide
directions for meeting every possible contingency during 
installation, operation or maintenance. When additional information
is desired to satisfy a problem not covered sufficiently for user's
purpose, please contact your nearest representative.

These instructions do not claim to cover all details or variations in the equipment, procedure, or process described, nor to provide directions for meeting every possible contingency 
during installation, operation or maintenance. When additional information is desired to satisfy a problem not covered sufficiently for user’s purpose, please contact your nearest 
representative.

Talon Large

Sheet 3 of 3

11/29/07

IMI-682

INSTALLATION INSTRUCTIONS

IMPORTANT: READ CAREFULLY BEFORE INSTALLING FIXTURE. 

WARNING

: Risk of Fire/Electric Shock. If not qualified, consult an electrician.

WARNING

: Risk of Electric Shock. Disconnect power at fuse or circuit breaker before installing or servicing.

WARNING

: Risk of Burn. Disconnect power and allow fixture to cool before changing bulb or handling fixture.

WARNING

: Risk of Personal Injury. Fixture may become damaged and/or unstable if not installed properly. Tighten all fixture components 

to their recommended torque values.

WARNING

: Risk of Fire/Electrical Shock. Upside down installation can result in overheating or accumulation of water in fixture. 

Install right side up.

NOTE: Specifications and dimensions subject to change without notice.

Visit our web site at www.cooperlighting.com

Customer First Center  1121 Highway 74 South  Peachtree City, GA  30269  770.486.4800  FAX  770.486.4801    

ADH071365

FIG. 8

Remove Optic, Rotate
To Desired Position
And Fasten Into Place

FIG. 6

Plug-In Starter

Thumbscrews

FIG. 7

Remove Optic, Rotate
To Desired Position
And Fasten Into Place