Specifications and Dimensions subject to change without notice.

ADC041424

PHOTOMETRICS

ORDERING INFORMATION

ORDERING MATRIX

12 " SQUARE

GC/GW

C a n d l e p o w e r   D i s t r i b u t i o n

Test No. 766618
HPGC-150N-120V

Lamp=150W HPS

Lumens=16000

5

4

3

2

1

0

1

2

3

4

5

5      4      3      2      1      0      1      2      3      4      5

A B C D E

F

F o o t c a n d l e   Ta b l e

Select mounting height and read across for footcandle values

of each isofootcandle line.
Mounting

Height

Footcandle Values for

GC-2

Isofootcandle Lines
A

B

C

D

E

F

6'

22.50

11.25

4.50

2.25

1.13

0.45

9'

10.00

5.00

2.00

1.00

0.50

0.20

12'

5.63

2.81

1.13

0.56

0.28

0.11

Notes: 

For additional options, consult your Cooper Lighting Representative. Specifications and dimensions subject to change without notice.

Products also available in non-US voltages and 50Hz for international markets.

1. Supplied from factory with deep casting. 2. Not available with white lens. 3. Only available in HPF.