Cooper Lighting FAIL-SAFE FMS24LP Скачать руководство пользователя страница 2

Fail-Safe • Customer First Center • 1121 Highway 74 South • Peachtree City, GA 30269 • TEL 770.486.4800 • FAX 770.486.4801

04/13/2007 5:12:05 PM

Specifications and Dimensions subject to change without notice.

ADC041622

PHOTOMETRICS

ORDERING INFORMATION

FMS24LP

1000

1500

2000

2500

3000

C a n d l e p o w e r   D i s t r i b u t i o n

Z o n a l   L u m e n   S u m m a r y

Zone

Lumens

%Lamp

%Fixt

0-30

2362

21.1

31.7

0-40

3882

34.7

52.1

0-60

6499

58.0

87.2

0-90

7450

66.5

100.0

90-180

0

0.0

0.0

0-180

7450

66.5

100.0

Test No. 168P134
FMS24LP-432-120

Lamp=(4) F032/35K

Lumens=2800

Spacing Criteria

=1.3 =1.2

Efficiency=66.5%

rc

rw

RCR

0
1
2
3
4
5
6
7
8
9

10

C o e f f i c i e n t   o f   U t i l i z a t i o n

C a n d l e p o w e r

Deg.

0

2962

2962

5

2943

2966

15

2846

2938

25

2638

2823

35

2278

2561

45

1744

2161

55

1127

1429

65

613

685

75

271

303

85

40

42

90

0

0

80%

70%

50%

30%

10%

0%

70

50

30

10

70

50

30

10

50

30

10

50

30

10

50

30 10

0

79

79

79

79

77

77

77

77

74

74

74

71

71

71

68

68

68

67

74

71

69

67

72

70

68

66

67

65

64

64

63

62

62

61

60

59

68

64

60

57

67

62

59

56

60

57

55

58

56

53

56

54

52

51

63

57

52

49

61

56

52

48

54

50

47

52

49

47

51

48

46

45

58

51

46

42

57

50

45

42

49

45

41

47

44

41

46

43

40

39

53

46

40

36

52

45

40

36

44

39

36

42

38

35

41

38

35

34

49

41

36

32

48

40

35

31

39

35

31

38

34

31

37

34

31

29

45

37

32

28

44

36

31

28

35

31

27

35

30

27

34

30

27

26

42

33

28

24

41

33

28

24

32

27

24

31

27

24

30

26

24

22

39

30

24

21

38

29

24

21

29

24

21

28

24

21

27

23

20

19

36

27

22

18

35

27

22

18

26

21

18

25

21

18

25

21

18

17

rc=Ceiling reflectance, rw=Wall reflectance, RCR=Room cavity ratio 
CU Data Based on 20% Effective Floor Cavity Reflectance.

FNL

= Fluorescent Night Light

(Lamp by others.)

LNL

= LED Night Light (50,000 hrs.)

 provided by Cooper

224=(2) 24W HO Lamps

414=(4) 14W Lamps

324=(3) 24W HO Lamps

328=(3) 28W Lamps
428=(4) 28W Lamps
254=(2) 54W HO Lamps
354=(3) 54W HO Lamps
454=(4) 54W HO Lamps

424=(4) 24W HO Lamps

Отзывы: