background image

Suspended T5/T8 Luminaire

Install first fixture with two AC cable

assemblies, then second fixture with

one additional cable.

Bend out tapered aligning tabs and

fit into aligner slots. (Fixture 2 is now

supported by fixture 1 at the joint.)

Make electrical connections.

End Caps: Slide into end of fixture

and secure with two 10-32 x 3/8”

self tapping screws.

Set in place.

*T5 Shown

END CAP

Slide-N-Lock

TM

DUST COVER

Tuck wires into wire cavity, slide both

fixtures together. Secure fixtures using

two 10-32 x 3/8” screws and nuts. 

Tighten 1/4 turn past hand-tight.

NOTE: Remove film from optic before installing.

To Install - set in place over lamps.

The Slide-N-Lock   comes pre-set from the factory to the customer specified optical setting.

To field adjust the optic, depress the control notch and slide tab to desired setting (instructions

located on optic).

Break off appropriate KO, slide power cord through KO opening, then

secure power cord with strain relief.

Note: Location of the KO’s varies depending on fixture

*For continuous rows see joining sheet.

*For continuous rows see joining sheet.

Not all options available. Please consult your Cooper Lighting Representative for availability. Specifications and Dimensions subject to change without notice.

5/8”-7/8” KNOCK OUT

INSTALL LAMPS

JOINING

POWER DROPS / KNOCK-OUTS

MOUNT SPACING

FIXTURE LENGTH

FIXTURE LENGTH

SAMPLE ROW

Power

96” SPACING

96” SPACING

 INSTALLATION

JAYLUM

ADE130026

TM

TAB