Suspended T5/T8 Luminaire
Install first fixture with two AC cable
assemblies, then second fixture with
one additional cable.
Bend out tapered aligning tabs and
fit into aligner slots. (Fixture 2 is now
supported by fixture 1 at the joint.)
Make electrical connections.
End Caps: Slide into end of fixture
and secure with two 10-32 x 3/8”
self tapping screws.
Set in place.
*T5 Shown
END CAP
Slide-N-Lock
TM
DUST COVER
Tuck wires into wire cavity, slide both
fixtures together. Secure fixtures using
two 10-32 x 3/8” screws and nuts.
Tighten 1/4 turn past hand-tight.
NOTE: Remove film from optic before installing.
To Install - set in place over lamps.
The Slide-N-Lock comes pre-set from the factory to the customer specified optical setting.
To field adjust the optic, depress the control notch and slide tab to desired setting (instructions
located on optic).
Break off appropriate KO, slide power cord through KO opening, then
secure power cord with strain relief.
Note: Location of the KO’s varies depending on fixture
*For continuous rows see joining sheet.
*For continuous rows see joining sheet.
Not all options available. Please consult your Cooper Lighting Representative for availability. Specifications and Dimensions subject to change without notice.
5/8”-7/8” KNOCK OUT
INSTALL LAMPS
JOINING
POWER DROPS / KNOCK-OUTS
MOUNT SPACING
FIXTURE LENGTH
FIXTURE LENGTH
SAMPLE ROW
Power
96” SPACING
96” SPACING
INSTALLATION
JAYLUM
ADE130026
TM
TAB