Cooper Lighting Corelite ADE080932 Скачать руководство пользователя страница 2

Bracing
(by others)

Sheet rock

Metalux DF series 
frame kit

Screw
(by others)

Installation Instructions

Warning

:  Before starting any work ensure that 

all sources of power are turned off.  All work must

 

meet local/national codes and be performed by a 
certified electrician.  

Do not

 mount fixtures 

vertically. 

Sheet 2 of 4

R1  Ultra Shallow Recessed
Concealed Ceiling Installation Instructions

1' x 4', 2' x 2', 2' x 4'

Ceiling

Appropriate fasteners
(x6)

Section view

Hole Cut-out dimensions

Cut-outs dimensions are exact.  In order to maintai

n the precision fit of the Metalux DF series frame 

kit, 

bracing in ceiling 

must precisely match

 above dimensions.  Shims may be used to maintain t

olerances.  

1' x 4'

2' x 2'

2' x 4'

1.  After appropriate cut-out is made in sheet rock

, insert Metalux DF series frame kit into cut-out a

nd 

     secure bracket to bracing using appropriate fa

steners(by others).  Use shims to prevent the brack

et 

     joints from opening.

Securing Metalux DF Series Frame Kit to Structure i

n Ceiling

3

1/8"

16 " - 0"

24

+

1/8"

+

48

0"

-

"

4

1

1/8"

+

12

0"

-

"

16

3

1/8"

+

24

0"

-

"

16

3

1/8"

+

24

0"

-

"

4

1

48

1
4 " - 0"

+1/8"

Cooper Lighting
1121 Highway 74 South
Peachtree City, GA 30269
P: 770-486-4800
www.cooperlighting.com

Corelite
4675 Holly St
Denver, CO 80216
P: 303-393-1522
www.corelite.com

ADE080932   REV(A)

Содержание Corelite ADE080932

Страница 1: ...nd 2x2 assemble in same manner Corner bracket x4 4ft section 1ft section 1 To assemble Metalux DF series frame kit firmly insert corner bracket into one side of long sectio n Ensure corner bracket it facing the inside to the extrusion sections as shown in detail A Corne r bracket will lock into place when fully positioned 2 Firmly insert short section to other side of co rner bracket Repeat until c...

Страница 2: ...he precision fit of the Metalux DF series frame kit bracing in ceiling must precisely match above dimensions Shims may be used to maintain t olerances 1 x 4 2 x 2 2 x 4 1 After appropriate cut out is made in sheet rock insert Metalux DF series frame kit into cut out a nd secure bracket to bracing using appropriate fa steners by others Use shims to prevent the brack et joints from opening Securing M...

Страница 3: ...DF series fr ame kit Side View Ground screw Conduit by others Electrical cover plate Conduit from power source by others Corelite R1 Ultra Shallow Fixture Metalux DF series Frame Kit 1 Unless top access is available fixture must be wired prior to installing fixture into Metalux DF series frame kit 2 Remove electrical cover plate from fixture and attach conduit supplied by others unless pre ordered wi...

Страница 4: ...t 4 of 4 R1 Ultra Shallow Recessed Concealed Ceiling Installation Instructions 1 x 4 2 x 2 2 x 4 1 Gently remove lens from fixture and store in a sa fe place 2 Slide lamp contacts into sockets at both ends of fixture and rotate lamp to secure in socket 3 Snap lens back into place around plastic end caps Slide lamp into socket and rotate Cooper Lighting 1121 Highway 74 South Peachtree City GA 30269 P...

Отзывы: