Cooper Lighting Corelite ADE080932 Скачать руководство пользователя страница 1

Installation Instructions

Warning

:  Before starting any work ensure that 

all sources of power are turned off.  All work must

 

meet local/national codes and be performed by a 
certified electrician.  

Do not

 mount fixtures 

vertically. 

Sheet 1 of 4

R1  Ultra Shallow Recessed
Concealed Ceiling Installation Instructions

1' x 4', 2' x 2', 2' x 4'

Sheet 
rock

Ceiling bracing
(by others)

Metalux DF Series
Frame kit

Corelite Ultra-shallow
recessed fixture
(R1 1' x 4' fixture shown)

Exploded View and Part call-out

Cut-out Dimensions
on Page 2

???????????

?????????

1x4 assembly shown. 

2x4 and 2x2 assemble 
in same manner.

Corner bracket
(x4)

4ft. section

1ft. section

1.  To assemble Metalux DF series frame kit, firmly

 insert corner bracket into one side of long sectio

n.  

     Ensure corner bracket it facing the inside to 

the extrusion sections as shown in detail A.  Corne

r bracket 

     will lock into place when fully positioned.  
2.  Firmly insert short section to other side of co

rner bracket.  Repeat until ceiling bracket is full

y assembled.

Assembling the Metalux

TM

 DF Series Frame Kit

?

Fixture Size

1x4
2x2
2x4

Frame Kit Part #

DF-24W-U

DF-22W-U

DF-14W-U

Cooper Lighting
1121 Highway 74 South
Peachtree City, GA 30269
P: 770-486-4800
www.cooperlighting.com

Corelite
4675 Holly St
Denver, CO 80216
P: 303-393-1522
www.corelite.com

ADE080932   REV(A)

Содержание Corelite ADE080932

Страница 1: ...nd 2x2 assemble in same manner Corner bracket x4 4ft section 1ft section 1 To assemble Metalux DF series frame kit firmly insert corner bracket into one side of long sectio n Ensure corner bracket it facing the inside to the extrusion sections as shown in detail A Corne r bracket will lock into place when fully positioned 2 Firmly insert short section to other side of co rner bracket Repeat until c...

Страница 2: ...he precision fit of the Metalux DF series frame kit bracing in ceiling must precisely match above dimensions Shims may be used to maintain t olerances 1 x 4 2 x 2 2 x 4 1 After appropriate cut out is made in sheet rock insert Metalux DF series frame kit into cut out a nd secure bracket to bracing using appropriate fa steners by others Use shims to prevent the brack et joints from opening Securing M...

Страница 3: ...DF series fr ame kit Side View Ground screw Conduit by others Electrical cover plate Conduit from power source by others Corelite R1 Ultra Shallow Fixture Metalux DF series Frame Kit 1 Unless top access is available fixture must be wired prior to installing fixture into Metalux DF series frame kit 2 Remove electrical cover plate from fixture and attach conduit supplied by others unless pre ordered wi...

Страница 4: ...t 4 of 4 R1 Ultra Shallow Recessed Concealed Ceiling Installation Instructions 1 x 4 2 x 2 2 x 4 1 Gently remove lens from fixture and store in a sa fe place 2 Slide lamp contacts into sockets at both ends of fixture and rotate lamp to secure in socket 3 Snap lens back into place around plastic end caps Slide lamp into socket and rotate Cooper Lighting 1121 Highway 74 South Peachtree City GA 30269 P...

Отзывы: