![Cooper Lighting Corelite ADE080932 Скачать руководство пользователя страница 1](http://html.mh-extra.com/html/cooper-lighting/corelite-ade080932/corelite-ade080932_installation-instructions_2662542001.webp)
Installation Instructions
Warning
: Before starting any work ensure that
all sources of power are turned off. All work must
meet local/national codes and be performed by a
certified electrician.
Do not
mount fixtures
vertically.
Sheet 1 of 4
R1 Ultra Shallow Recessed
Concealed Ceiling Installation Instructions
1' x 4', 2' x 2', 2' x 4'
Sheet
rock
Ceiling bracing
(by others)
Metalux DF Series
Frame kit
Corelite Ultra-shallow
recessed fixture
(R1 1' x 4' fixture shown)
Exploded View and Part call-out
Cut-out Dimensions
on Page 2
???????????
?????????
1x4 assembly shown.
2x4 and 2x2 assemble
in same manner.
Corner bracket
(x4)
4ft. section
1ft. section
1. To assemble Metalux DF series frame kit, firmly
insert corner bracket into one side of long sectio
n.
Ensure corner bracket it facing the inside to
the extrusion sections as shown in detail A. Corne
r bracket
will lock into place when fully positioned.
2. Firmly insert short section to other side of co
rner bracket. Repeat until ceiling bracket is full
y assembled.
Assembling the Metalux
TM
DF Series Frame Kit
?
Fixture Size
1x4
2x2
2x4
Frame Kit Part #
DF-24W-U
DF-22W-U
DF-14W-U
Cooper Lighting
1121 Highway 74 South
Peachtree City, GA 30269
P: 770-486-4800
www.cooperlighting.com
Corelite
4675 Holly St
Denver, CO 80216
P: 303-393-1522
www.corelite.com
ADE080932 REV(A)