background image

6

www.cooperbussmann.com/BussmannWirelessResources

3A1577Rev1.9

Cooper Bussmann BU-905U-L-T Transmitter Quick Start Guide

Resetting Your Unit to Factory Defaults

To reset the default factory configuration:

1. Set the RSSI rotary switch to position 0 using a screwdriver.

2. Power on the BU-905U-L-T transmitter.

3. The BU-905U-L-T transmitter flashes all LEDs at medium flash (i.e., 1.6Hz).

NOTE:

If the LEDs do not flash, you must repeat steps 1 and 2 until the LEDs flash before continuing.

4. Set the RSSI rotary switch to another position (i.e. position 1) within 5 seconds.

5. Set the RSSI rotary switch to position 0 within another 5 seconds.

6. The BU-905U-L-T transmitter lights all LEDs for 2 seconds before returning to normal operation.

NOTE:

If the LEDs do not light for 2 seconds, you must repeat the process from step 1 until the LEDs light before continuing.

7. You can now link the transmitter and receiver units.

Linking Your Transmitter and Receiver Units

You must reset the transmitter unit to factory defaults (to disable encryption) before linking the transmitter and receiver units.
For more information, see the previous section.

NOTE:

You must complete the linking process in 60 seconds.

To link the transmitter and receiver units:

1. Press and hold down the RSSI Pushbutton on the receiver.

2. Power on the receiver while holding down the RSSI Pushbutton

3. Release the RSSI Pushbutton as soon as the Receiver LEDs flash (within 5 seconds of powering the receiver).

4. The receiver will flash all LEDs for a maximum 60 seconds while it tries to link to the transmitter.

5. Power on the transmitter. The transmitter sends a special “Link” message to allow the receiver to recognize the transmitter.

6. When the units link, the receiver lights all LEDs for 2 seconds before returning to normal operation.

NOTE:

If the receiver LEDs continue flashing within the 60 seconds, the units are not linked and you should retry the linking process by powering

the transmitter off and on again. If you exceed the 60 seconds, you must restart the linking process from step 1.

7. You can now bench test your configuration before deploying.

Safety Information

Thank you for selecting the BU-905U-L-T transmitter for your telemetry needs. We trust it will give you many years of valuable service. To ensure
your BU-905U-L transmitter enjoys a long life, double-check ALL your connections with the user’s manual before powering on the unit.

WARNING:

Incorrect termination of supply wires may cause internal damage and will void warranty.

Exposure to RF energy is an important safety consideration. The FCC has adopted a safety standard for human exposure to radio frequency 
electromagnetic energy emitted by FCC regulated equipment as a result of its actions in Docket 93-62 and OET Bulletin 65 Edition 97-01.

FCC Notice when used in USA: 905U-L Wireless I/O Module

Part

Additional information

15

This device has been tested and found to comply with the limits for a Class B digital device, pursuant to Part15 of the FCC rules 
(Code of Federal Regulations 47CFR Part 15). Operation is subject to the condition that this device does not cause 
harmful interference.

90

This device has been type accepted for operation by the FCC in accordance with Part90 of the FCC rules (47CFR Part 90).
See the label on the unit for the specific FCC ID and any other certification designations.

Содержание BU-905U-L-T

Страница 1: ...3A1577Rev1 9 Cooper Bussmann BU 905U L T Transmitter Quick Start Guide Version 1 9 Read and Retain for Future Reference ...

Страница 2: ...k using a dedicated pair of transmitter and receiver units The basic steps for using your unit are 1 Connect the antenna power supply and transducer signals using the instructions in this document Power supply and transducer connection is described in the section Unit components and connections Antenna connection is described in the section Antenna installation For more information see the BU 905U...

Страница 3: ...r BU 905U L T Transmitter unit has the following components and terminal connections IMPORTANT ELECTRICAL SAFETY INFORMATION In order to comply with Electrical Safety Regulations this module must be installed in an Electrical AND Fire enclosure This enclosure may be a single or multiple enclosures Access to the module is to be made by a Service Person only ...

Страница 4: ...ition for example NOTE To avoid damaging the rotary switch use a screwdriver to change the position The rotary switch uses the following setpoint levels Position Lower Level mA Upper Level mA 1 4 8 6 4 2 6 4 8 0 3 8 0 9 6 4 9 6 11 2 5 11 2 12 8 6 12 8 14 4 7 14 4 16 0 8 16 0 17 6 9 17 6 19 2 SMA Antenna Connector at Top of Unit Indicator LEDs RS232 Configuration Port Rotary Switch for Setpoint Set...

Страница 5: ... LED Flashes Transmitting Message PG LED on Configuration Cable Connected Input LED ON Input LEDs i e D1 D2 SP AZ light when the corresponding input is active D1 Digital Input 1 is active Low D2 Digital Input 2 is active SP Analog Setpoint is active AZ Analog Input is zero mA All LEDs medium flash Medium speed flash 1 6Hz indicates the module is half way through the configuration process Medium fl...

Страница 6: ...ower on the transmitter The transmitter sends a special Link message to allow the receiver to recognize the transmitter 6 When the units link the receiver lights all LEDs for 2 seconds before returning to normal operation NOTE If the receiver LEDs continue flashing within the 60 seconds the units are not linked and you should retry the linking process by powering the transmitter off and on again I...

Страница 7: ...latory codes 2 The units are intended for Restricted Access Locations 3 The Wireless I O module is intended to be installed in a final enclosure rated IP54 before use outdoors 4 The Equipment shall be powered using an external Listed Power Supply with LPS outputs or a Class 2 Power Supply 5 The Wireless I O module must be properly grounded for surge protection before use Unit Specifications Input ...

Страница 8: ... assistance is available to all customers Staffed by degreed engineers this application support is available Monday Friday 8 00 a m 5 00 p m CT Contact s Phone 636 527 1270 s Fax 636 527 1607 s E mail fusetech cooperindustries com s Live Chat www cooperbussmann com Online Resources Visit www cooperbussmann com for the following resources s Product search cross reference s Product technical materia...

Отзывы: