background image

www.cooperbussmann.com/wirelessresources

Cooper Bussmann 1050E-T Unmanaged Ethernet Switch User Manual

13

Rev 1.1.5

a

ppENDIx

 a - GLOSSarY

Term

Definition

100Base-TX

100Base-TX is a Fast Ethernet cabling standard. 100Base-TX devices can transfer data at a 
rate of up to 100 Mbps, and use two wire-pairs of wires inside a category 5 or above cable. 

10Base-T

10Base-T is an Ethernet cabling standard. 10Base-T devices can transfer data at a rate of up 
to 10 Mbps, and use twisted pairs of wires in their Ethernet cabling.

AWG

American wire gauge (AWG), also known as the Brown & Sharpe wire gauge, is a standard-
ized wire gauge system used predominantly in the United States and Canada for the  
diameters of round, solid, nonferrous, electrically conducting wire.

CSMA/CD

Carrier Sense Multiple Access/Collision Detection is the access method used on an Ethernet 
network. A network device transmits data after detecting that a channel is available. However, 
if two devices transmit data simultaneously, the sending devices detect a collision and 
retransmit after a random time delay.

DIN rail

A DIN rail is a metal rail of a standard type widely used for mounting circuit breakers and 
industrial control equipment inside equipment racks.

ESD

Electrostatic discharge (ESD) is discharge of static electricity from a outside source, such as 
human hands, into an integrated circuit, often resulting in damage to the circuit. 

FCC

The Federal Communications Commission (FCC) is the US agency that regulates interstate 
and international wire, radio, and other broadcast trasmissions, including telephone,  
telegraph, and telecommunications.

Full Duplex

A full-duplex (or double-duplex) system allows communication in both directions and, unlike 
half-duplex, allows this to happen simultaneously. Land-line telephone networks are exam-
ples of full-duplex, since they allow both callers to speak and be heard at the same time.

IEEE

Institute of Electrical and Electronics Engineers, New York, www.ieee.org. A membership 
organization that includes engineers, scientists and students in electronics and allied fields. 
It has more than 300,000 members and is involved with setting standards for computers and 
communications.

MDI/MDIX

Medium Dependent Interface (MDI) describes the interface (both physical and electrical) in 
a computer network from a physical layer implementation to the physical medium used to 
carry the transmission. Ethernet over twisted pair also defines a medium dependent interface 
crossover (MDIX) interface. Auto-MDIX ports on newer network interfaces detect if the con-
nection would require a crossover, and automatically chooses the MDI or MDIX configuration 
to properly match the other end of the link.

RJ-45

Standard connectors used in Ethernet networks. RJ-45 connectors are similar to standard 
RJ-11 telephone connectors, except that RJ-45 connectors can have up to eight wires, 
whereas telephone connectors have four wires.

Switch

A type of hub that efficiently controls the way multiple devices use the same network so that 
each can operate at optimal performance. A switch acts as a networks traffic cop. Rather 
than transmitting all the packets it receives to all ports as a hub does, a switch transmits 
packets to only the receiving port. 

UL

Underwriter Laboratories (UL) is one of several companies approved to perform safety testing 
by the US federal agency Occupational Safety and Health Administration (OSHA). 

Содержание 1050E-T

Страница 1: ...Read and Retain for Future Reference Cooper Bussmann 1050E T Unmanaged Ethernet Switch User Manual Version 1 1 5 ...

Страница 2: ... EXPLOSION HAZARD Do not disconnect equipment unless power has been removed or the area is known to be non hazardous WARNING EXPLOSION HAZARD Substitution of any components may impair suitability for Class I Division 2 WARNING EXPLOSION HAZARD The area must be known to be non hazardous before servicing replacing the unit and before installing WARNING Exposure to some chemicals may degrade the seal...

Страница 3: ...ns Failure to follow the instructions can cause personal injury and or property damage Proper Use Any unauthorized modifications to or use of this equipment outside its specified mechanical electrical or other operating limits may cause personal injury and or property damage including damage to the equipment Any such unauthorized modifications 1 constitute misuse and or negligence within the meani...

Страница 4: ... Mechanical Specifications 7 1 5 Order Information 7 Chapter 2 GETTING STARTED 8 2 1 Package Contents 8 2 2 Hardware Description 8 Front Panel 8 Top View 8 2 3 Wiring 9 Wiring the Power Inputs 9 Wiring the Fault Alarm Contact 9 Grounding 10 2 4 LED Indications Ports and Cabling 10 LED Indicators 10 Ports 10 Cabling 11 2 5 Mounting Installation 11 DIN rail Mounting 11 Wall Mount Plate Mounting 12 A...

Страница 5: ...ly switch to the secondary power input Flexible Mounting The Industrial Switch is extremely compact and can be mounted on a DIN rail or a wall so it is suitable for any space constrained environment Advanced Protection The power line of the 1050E T supports up to 3 000 Vdc EFT Electrical Fast Transient protection which secures equipment against unregulated voltage and makes systems safer and more ...

Страница 6: ...02 3u Flow Control and Backpressure IEEE 802 3x Transfer Rate 10 Mbps IEEE 802 3 100 Mbps with Auto Negotiation IEEE 802 3u Fault Alarm Fault Alarm Contact Alarm for System Events 1 Relay Output 1A MAX 24 Vdc or 24 Vac Ethernet Port Connectors RJ 45 Network Cabling 10Base T 2 pair UTP STP Cat 3 4 5 6 cable EIA TIA 568 100 ohm 100m 328 100Base TX 2 pair UTP STP Cat 5 6 cable EIA TIA 568 100 ohm 100...

Страница 7: ...Rating 40 C to 75 C 40 F to 167 F Humidity Rating 5 95 RH Non condensing Weight 0 43 kg 0 95 lb Power Supply Nominal Supply 12 Vdc to 48 Vdc Under Over Voltage Protection and Reverse Polarity Maximum Current Draw 450 mA 1 4 Mechanical Specifications The following diagram shows the exterior dimensions of the 1050E T Ethernet switch 1 5 Order Information Item Product Code Description Ethernet Switch...

Страница 8: ... Package Contents 1050E T Ethernet Switch x 1 Pluggable Terminal Block x 1 Wall Mounting Plate x 2 2 2 Hardware Description Front Panel The front panel of the 5 port 10 100BaseTX Industrial Switch is shown below Top View The top panel of the 5 port 10 100BaseTX Industrial Switch is equipped with one terminal block connector of two power inputs ...

Страница 9: ...r inputs to ensure that the fault alarm is not set Connect V to both pins 2 and 6 and then connect V to both pins 1 and 5 3 Tighten the wire clamp screws to prevent the wires from coming loose Wiring the Fault Alarm Contact The fault alarm contact is in the middle of terminal block connector as shown below The contact will be closed for normal operation and will open in the case of a power failure...

Страница 10: ...al ten LEDs display the network status These LEDs are located on the front panel of the switch and are described in the following table LED Color Description P1 Green On Power input 1 is active Off Power input 1 is inactive P2 Green On Power input 2 is active Off Power input 2 is inactive Fault Red On Power input 1 or 2 is inactive Off Power input 1 and 2 are both functional or no power inputs Lin...

Страница 11: ...ght through or crossover cabling see the following schematics Cabling Use the four twisted pair Category 5 cabling for RJ 45 port connection The cable length between the switch and the link partner switch hub or workstation must be less than 100m 328 ft 2 5 Mounting Installation DIN rail Mounting The 1050E T ships from the factory with the DIN rail mount kit installed Follow these steps to mount t...

Страница 12: ...rack reverse steps above Wall Mount Plate Mounting Follow these steps to mount the switch using the wall mount plate Unscrew the screws to remove the DIN rail mount from the switch 1 Fit the wall mount plates to the top and bottom ends of the switch 2 Use the mounting screws to secure the wall mount plate to the switch 3 Mount using the wall mount holes provided To remove the wall mount plate reve...

Страница 13: ...mmunications Full Duplex A full duplex or double duplex system allows communication in both directions and unlike half duplex allows this to happen simultaneously Land line telephone networks are exam ples of full duplex since they allow both callers to speak and be heard at the same time IEEE Institute of Electrical and Electronics Engineers New York www ieee org A membership organization that in...

Страница 14: ...www cooperbussmann com wirelessresources Cooper Bussmann 1050E T Unmanaged Ethernet Switch User Manual 14 Notes Rev 1 1 5 ...

Страница 15: ...Fax 1 925 924 8502 Online Resources Visit www cooperbussmann com wirelessresources for the following resources and more User Manuals Installation Guides Configuration Software Datasheets Dimensional Drawings North America Latin America 5735 W Las Positas Suite 100 Pleasanton California 94588 USA Telephone 1 925 924 8500 elpro sales cooperindustries com Australia New Zealand Cooper Technology Centr...

Отзывы: