background image

Function buttons

1

2

 Each time the button is pressed, the operation 

 mode is selected in a sequence of  following:

   

  

3

MODE  Button    

 

4

5

ON/OFF Button

Operation starts when this button is pressed 

and stops when this button is pressed again.

NOTE:  

Heat mode is for Cooling & Heating  models only.

AUTO

COOL

DRY

HEAT

FAN 

NOTE: 

While the unit is running under SLEEP

mode, it would be cancelled if press the MODE,

FAN SPEED or ON/OFF button.

6

Active/Disable SLEEP function. 

SLEEP Button    

 

     Swing     Button

 

     Swing     Button

 

Used to stop or start horizontal louver move-

ment .

Active/Disable TURBO function. If pushing 

more than 2 seconds, the  SELF CLEAN  

function will be activated, pushing more than 

2 seconds again to disable.

TURBO/SELF CLEAN Button:

  

,

,

Used to stop or start vertical louver movement. 

When the vertical louver swing feature is 

activated, the display area of indoor unit 

displays    

   , flashes four times, then the 

IIII

temperature setting reverts back. If the vertical 

louver swing feature is stopped, it displays  LC   

and remains on for 3 seconds.

NOTE:

 For some units , the indoor units 

display               when the swing feature is 

activated, and display            when the swing

feature is stopped.          

,

,

,

,

1

2

4

5

3

9

10

8

6

7

11

12

13

14

15

TURBO

   SELF

 CLEAN

SLEEP

SILENCE

      FP

TIMER

  ON

TIMER

  OFF

LOCK

RESET

    LED

FOLLOW

      ME

   FAN

SPEED

SWING

MODE

TEMP

ON/OFF

SWING

,

,

,

,

This function can maintain the most comfortable 

temperature and save energy. This function is 

available on COOL, HEAT or AUTO mode only .

For the detail, see       Sleep operation   in

   USER S MANUAL .  

,

,,

,,

,,

,,

Содержание SOPHIA

Страница 1: ...HIGH WALL DUCTLESS AIR CONDITIONING HEATING SYSTEM Quick Start Guide SOPHIA TURBO SELF CLEAN SLEEP SILENCE FP TIMER ON TIMER OFF LOCK RESET LED FOLLOW ME FAN SPEED SWING MODE TEMP ON OFF SWING ...

Страница 2: ...controller Specifications Function buttons Indicators on LCD How to use the buttons Auto operation Cooling Heating Fan operation Dehumidifying operation Adjusting air flow direction Timer operation SLEEP FRESH function LED FOLLOW ME function 14 TURBO SELF CLEAN function 14 ...

Страница 3: ...other materials block the signals from the remote controller to the indoor unit Prevent any liquid from falling into the remote controller Do not expose the remote controller to direct sunlight or heat If the infrared signal receiver on the indoor unit is exposed to direct sunlight the air conditioner may not function properly Use curtains to prevent the sunlight from falling on the receiver If ot...

Страница 4: ...F 86 F 4 Full function of LCD Liquid Crystal Display Environment Signal Receiving Range Performance Feature O O 23 F 140 F NOTE Buttons design might be slightly different from the actual one you purchased depending on individual models All the functions described are accomplished by the indoor unit If the indoor unit has no this feature there is no corresponding operation happened when press the r...

Страница 5: ...ivated pushing more than 2 seconds again to disable TURBO SELF CLEAN Button Used to stop or start vertical louver movement When the vertical louver swing feature is activated the display area of indoor unit displays flashes four times then the IIII temperature setting reverts back If the vertical louver swing feature is stopped it displays LC and remains on for 3 seconds NOTE For some units the in...

Страница 6: ...cooling and heating capacity During the heating operation only when the setting mode is HEAT If pushing this button more than 2 seconds the FP function is activated The unit will operate at high fan speed with the temperature automatically set to O O 8 C 46 F The display window of indoor unit will display FP For the unit without display area the Defrost indicator light will be keeping on for 2 sec...

Страница 7: ...0 minutes increments When the setting time displays 10H each press will increase the auto timed setting 60 minutes increments To cancel the auto timed program simply adjust the auto off time to 0 0 1 2 4 5 3 9 10 8 6 7 11 12 13 14 15 TURBO SELF CLEAN SLEEP SILENCE FP TIMER ON TIMER OFF LOCK RESET LED FOLLOW ME FAN SPEED SWING MODE TEMP ON OFF SWING 14 15 LOCK Button When you press the recessed LOC...

Страница 8: ...Displayed by pressing the ON OFF button Press the ON OFF button again to remove Displays the selected fan speed AUTO no display and three fan speed levels LOW MED HIGH can be indicated The fan speed is AUTO when the operating mode is either AUTO or DRY Displayed when SILENCE function is activated Displayed under sleeping operation Press the SLEEP button again to remove Note of clear presentation B...

Страница 9: ...ator on the display panel of the indoor unit starts flashing 1 Press the MODE button to select Auto 2 Press the UP DOWN button to set the desired temperature The temperature can O O be set within a range of 62 F 86 F in 1 F increments 3 Press the ON OFFbutton to start the air conditioner O 1 In the Auto mode the air conditioner can logically choose the mode of Cooling Fan and Heating by sensing th...

Страница 10: ... 1 2 2 Use the SWING and SWING buttons to adjust the desired airflow direction 1 When push the SWING button the horizontal louver changes 6 degree in angle for each push If pushing more than 2 seconds the louver will automatically swing up and down 2 When push the SWING button the vertical louver changes 6 degree in angle for each push If pushing more than 2 seconds the louver will automatically s...

Страница 11: ...al h will disappear and the set temperature will re appear on the LCD display window To set the Auto on time To set the Auto off time 1 Press the TIMER OFF button The remote controller shows TIMER OFF the last Auto off setting time and the signal h will be shown on the LCD display area Now it is ready to reset the Auto off time to stop the operation 2 Push the TIMER OFF button again to set desired...

Страница 12: ...ant the unit to turn on automatically before you return home The air conditioner will automatically start operating at the set time To start the air conditioner in 6 hours 1 Press the TIMER ON button the last setting of starting operation time and the signal h will show on the display area 2 Press the TIMER ON button to display 6 0h on the TIMER ON display of the remote controller 3 Wait for 3 sec...

Страница 13: ...mple On Stop 2 hours later after setting Set To stop the air conditioner 2 hours after setting and start it again 10 hours after setting 1 Press the TIMER OFF button 2 Press the TIMER OFF button again to display 2 0h on the TIMER OFF display 3 Press the TIMER ON button 4 Press the TIMER ON button again to display 10h on the TIMER ON display 5 Wait for 3 seconds and the digital display area will sh...

Страница 14: ...setting 1 Press the TIMER ON button 2 Press the TIMER ON button again to display 2 0h on the TIMER ON display 3 Press the TIMER OFF button 4 Press the TIMER OFF button again to display 5 0h on the TIMER OFF display 5 Wait for 3 seconds and the digital display area will show the temperature again The TIMER ON OFF indicator remains on and this function is activated Off Stop Start 2 hours later after...

Страница 15: ...ill cancel the Follow Me function automatically Press this button less than 2nds will initiate TURBO function And if keep pressing this button more than 2nds the SELF CLEAN function is initiated Turbo function enables the unit to reach the preset temperature at cooling or heating operation in the shortest time if the indoor unit does not support this function there is no corresponding operation ha...

Страница 16: ...tops the fan keeps air flowing past the thermostat What temperature is displayed on the remote controller The remote always displays your desired indoor temperature You may view current indoor and outdoor temperatures on the indoor unit s Front Panel Display What happens if the remote is lost or damaged Use the Manual Override button to manually operate the unit Lift up the front panel section on ...

Отзывы: