Clean and maintenance

1

2

3

4

Open panel

Pull out the panel to a certain 

● Use dust catcher or water to
   clean the filter. 
● When the filter is very dirty use
   the water (below 113°F(45°C)) 
   to clean it, and then put it in a 

   shady and cool place to dry.

panel cover tightl

y

.

   operation environment, clean frequency can be increased.

WARNING

Содержание GWH09KF-A3DNB4A

Страница 1: ...GH WALL DUCTLESS AIR CONDITIONING HEATING SYSTEM OWNER S MANUAL Models GWH09KF A3DNB4A 115V GWH12KF A3DNB4A 115V GWH09KF D3DNB4F 230V GWH12KF D3DNB4F 230V GWH18KG D3DNB4F 230V GWH24KG D3DNB4A 230V ALI...

Страница 2: ...3DNB4A I GWH12KF A3DNA5A O GWH09KF D3DNB4F 230V System Includes GWH09KF D3DNB4F I GWH09KF D3DNA5F O GWH12KF D3DNB4F 230V System Includes GWH12KF D3DNB4F I GWH12KF D3DNA5F O GWH18KG D3DNB4F 230V System...

Страница 3: ...ons on display screen 7 Introduction for buttons on remote controller 8 Function introduction for combination buttons 12 Operation guide 13 Replacement of batteries in remote controller 13 Emergency o...

Страница 4: ...s situation that if not avoided could result in death or serious injury Indicates a hazardous situation that if not avoided may result in minor or moderate injury Indicates important but not hazard re...

Страница 5: ...pliance Cleaning and user maintenance shall not be made by children without supervision years and above and persons with reduced physical sensory or mental capabilities or lack of experience and knowl...

Страница 6: ...amage Precautions WARNING conditioner and disconnect power immediately and then If the air conditioner operates under abnormal conditions it may cause malfunction electric shock or fire hazard Do not...

Страница 7: ...ables before using the air conditioner An all pole disconnection switch having a contact separation Must follow the electric safety regulations when installing the unit grounding wire of power socket...

Страница 8: ...al national wiring regulations requirement of National Electrical Codes NEC and local electrical codes by authorized personnel only Precautions WARNING wire which can t be used for other purposes The...

Страница 9: ...89 6 73 4 32 23 109 4 78 8 43 26 Maximum heating 80 6 27 75 2 64 4 24 18 The operating temperature range outdoor temperature for cooling only unit is 64 4 F 18 C 109 4 F 43 C for heat pump unit is 19...

Страница 10: ...different from above graphics please refer to actual products Indoor Unit air inlet panel horizontal louver air outlet heating indicator temp indicator cooling indicator power indicator receiver windo...

Страница 11: ...e X FAN is same with BLOW 9 TEMP button 10 TIMER button 11 TURBO button 12 SLEEP button 13 LIGHT button 7 HEALTH SAVE button 6 button FAN OPER AUTO HEALTH AIR FILTER TURBO ON OFF X FAN HOUR HUMIDITY U...

Страница 12: ...t indicator on indoor unit is ON You can press or button to adjust set temperature Press FAN button to adjust fan speed Press button to adjust swing angle Cooling only unit can t receive the signal fo...

Страница 13: ...igh medium or low speed according to ambient temperature Fan speed under dry mode is low speed 5 Press this button to start or stop up down swing function The remote controller defaults to simple swin...

Страница 14: ...swing Horizontal louver of air conditioner will swing left right automatically at the maximum angle When selecting position swing Horizontal louver of air conditioner will stop at that position as sho...

Страница 15: ...ambient temperature When selecting by remote controller temperature indicator on indoor unit displays outdoor ambient temperature SAVE function Under cool mode press SAVE button and the unit will oper...

Страница 16: ...isappear Press this button again to turn on the light for indoor unit s display icon on remote controller will be displayed Child lock function Switchover function for temperature display Press and bu...

Страница 17: ...2 Replace two 7 AAA 1 5V dry batteries and make sure the position of polar and polar are correct 3 Reinstall the cover of battery box signal sender battery Cover of battery box remove reinstall Durin...

Страница 18: ...ated object to press the auto button Clean and maintenance Turn off the air conditioner and disconnect the power before cleaning the air conditioner to avoid electric shock Do not wash the air conditi...

Страница 19: ...to a certain Use dust catcher or water to clean the filter When the filter is very dirty use the water below 113 F 45 C to clean it and then put it in a shady and cool place to dry panel cover tightly...

Страница 20: ...nage pipe is damaged 1 Disconnect power supply 3 Check whether mounting bracket for outdoor unit is damaged or corroded If yes please contact dealer Notice for recovery 1 Many packing materials are re...

Страница 21: ...oom Pull out the plug Reinsert the plug after about 3min and then turn on the unit again Signal receiving range is 8m Remove obstacles Select proper angle and point the remote controller at the re cei...

Страница 22: ...emperature and hum idity is high Because indoor air is cooled rapidly After a while indoor temperature and humidity will be decrease and mist will disappear Phenomenon Check items Solution Set temper...

Страница 23: ...unit again Outdoor unit has vapor Heating mode is turned on During defrosting under he ating mode it may generate vapor which is a normal phenomenon Water flowing noise Air conditioner is turned on or...

Страница 24: ...he unit If not please It can be eliminated after restarting the unit If not please It can be eliminated after restarting the unit If not please It can be eliminated after restarting the unit If not pl...

Страница 25: ...charge the heat to the room The alice heating capacity decreases as the outdoor temperature decreases During extreme cold outdoor temperatures you may need an additional heating source to supplement t...

Страница 26: ...can stick to coil fins and make the unit work up to 15 harder 5 Rearrange the room Furniture that obstructs airflow means you could be heating and cooling the back of a chair or the front of a sofa i...

Страница 27: ...ect in materials or workmanship under normal use and maintenance as follows All warranty periods begin on the date of original installation If the date cannot be verified the warranty period begins on...

Страница 28: ...age conditions blown fuses open circuit breakers or damages due to the inadequacy or interruption of electrical service 6 Failure or damage due to floods winds fires lightning accidents corrosive envi...

Отзывы: