Conditions
Indoor:DB27°C/WB19°C
Indoor air flow:Super High
Pipe length: 5m
Outdoor temp.(°C)
Capacity ratio (%
)
Outdoor temp.(
o
C)
30
40
50
60
70
80
90
100
110
120
-22
-15
-10
-5
0
7
15
20
24
Conditions
Indoor:DB20°C/WB15°C
Indoor air flow:Super High
Pipe length: 5m
Cooling
Heating
Heating operation ambient temperature range is -22ºC~24ºC
2.4 Cooling and Heating Data Sheet in Rated Frequency
Rated cooling
condition(
o
C)
(DB/WB)
Model
Pressure of gas pipe
connecting indoor and
outdoor unit
Inlet and outlet pipe
temperature of heat
exchanger
Fan speed of
indoor unit
Fan speed of
outdoor unit
Compressor
frequency
(Hz)
Indoor
Outdoor
P (MPa)
T1 (
o
C)
T2 (
o
C)
27/19
35/24
12K
0.8 ~ 1.1
11 to 14
38 to 41
Super High
High
72
18K
0.8
~
1.0
12 to 14
80 to 40
52
Rated heating
condition(
o
C)
(DB/WB)
Model
Pressure of gas pipe
connecting indoor and
outdoor unit
Inlet and outlet pipe
temperature of heat
exchanger
Fan speed of
indoor unit
Fan speed of
outdoor unit
Compressor
frequency
(Hz)
Indoor
Outdoor
P (MPa)
T1 (
o
C)
T2 (
o
C)
20/15
7/6
12K
2.8 ~ 3.2
38 to 41
2 to 5
Super High
High
77
18K
2.2
~
2.4
70 to 40
1 to 5
65
Instruction:
T1: Inlet and outlet pipe temperature of evaporator
T2: Inlet and outlet pipe temperature of condenser
P: Pressure at the side of big valve
Connection pipe length: 5 m.
Cooling:
Heating: