background image

Maintenance and cleaning

Important: The chiller must be turned off at the mains before maintaining or cleaning. It is recommended
to clean and wipe out the chiller after any spillage inside or outside the appliance.

Once a month wipe the interior surfaces and door seal using a teaspoonful of bicarbonate of soda diluted
in a pint of warm water to remove any residues or odours.

The external casing can be cleaned with warm soapy water and protected by polish. Do not use scouring
powders which can scratch the surface.

Unplug and leave door open when not in use.

Periodically remove and wipe dry the drip tray from the underside of the chiller.

When not in use

If leaving the chiller unused for a prolonged period, unplug from mains, wipe dry and leave the door open.

This  product is supplied with a fitted plug which contains a 3A fuse. If
you are simply replacing the fuse, you must use a 3A fuse which has
been approved by ASTA to BS1362.

If the plug does not fit the socket or becomes damaged, a new plug
must be fitted. Replace the original plug with the correct plug for your
socket. If this is a 3-pin (square pin) 13A (BS1363) plug, you must make
sure that it is fitted with an ASTA approved 3A fuse.

If another type of plug is used, it must be protected by a 5A fuse, either
in the plug or at the distribution board.

1. Cut off the existing fitted plug.

2. The wires in the mains lead supplied with this appliance are coloured in accordance with the following
code (Figure 4):

GREEN/YELLOW = EARTH (E)

BLUE = NEUTRAL (N)

BROWN = LIVE (L)

This product must be earthed.

As the colours of the wires in the mains lead may not correspond with the colour markings identifying the
terminals in your new plug, proceed as follows.

The wire which is coloured GREEN or YELLOW/GREEN must be connected to the terminal which is
marked with the letter E or 

E

symbol or coloured GREEN or YELLOW/GREEN.

The wire which is coloured BLUE must be connected to the terminal in the plug which is marked with the
letter N or coloured BLACK or BLUE.

The wire which is coloured BROWN must be connected to the terminal which is marked with the letter L or
coloured RED or BROWN.

3. Ensure that the connections are tight and that no loose strands are left out of the terminals.

IF IN ANY DOUBT CONSULT A QUALIFIED ELECTRICIAN.

If the mains lead becomes damaged consult a qualified electrician.

Fuse and mains plug replacement