![Coolzone CZ51105 Скачать руководство пользователя страница 6](http://html1.mh-extra.com/html/coolzone/cz51105/cz51105_user-instructions_2661397006.webp)
Page 6
This product is supplied with a fitted plug which contains a 13A fuse. If
you are simply replacing the fuse, you must use a 13A fuse which has
been approved by ASTA to BS1362.
If the plug does not fit the socket or becomes damaged, a new plug must
be fitted. Replace the original plug with the correct plug for your socket. If
this is a 3-pin (square pin) 13A (BS1363) plug, you must make sure that it
is fitted with an ASTA approved 13A fuse.
If another type of plug is used, it must be protected by a 15A fuse, either in
the plug or at the distribution board.
1. Cut off the existing fitted plug.
2. The wires in the mains lead supplied with this appliance are coloured in accordance with the following
code (Figure 9):
GREEN/YELLOW = EARTH (E) BLUE = NEUTRAL (N) BROWN = LIVE (L)
This product must be earthed.
As the colours of the wires in the mains lead may not correspond with the colour markings identifying the
terminals in your new plug, proceed as follows.
The wire which is coloured GREEN or YELLOW/GREEN must be connected to the terminal which is
marked with the letter E or
E
symbol or coloured GREEN or YELLOW/GREEN.
The wire which is coloured BLUE must be connected to the terminal in the plug which is marked with the
letter N or coloured BLACK or BLUE.
The wire which is coloured BROWN must be connected to the terminal which is marked with the letter L or
coloured RED or BROWN.
3. Ensure that the connections are tight and that no loose strands are left out of the terminals.
IF IN ANY DOUBT CONSULT A QUALIFIED ELECTRICIAN.
If the mains lead becomes damaged consult a qualified electrician.
Fuse and mains plug replacement
FIGURE 9
Problem
Possible cause
Remedy
Appliance does not run
No power
Check power is switched ON
Faulty fuse
Check fuse in plug
Temperature control set to OFF
Turn thermostat setting higher
Chiller is not cold enough
Door is open for too long
Do not open door needlessly
Located too near a heat source
Relocate appliance
Inadequate airflow around appliance
Thermostat set too high
Lower temperature by turning
control towards LO
Abnormal noise and
Appliance not level
Choose a level surface
vibration
Cooling tubes touching cabinet
Carefully ease away tubes from
or other parts
other parts
Troubleshooting