KIT CONFIGURATION HT66-470 (415VAC DELTA)
KIT CONFIGURATION HT66-470 (230VAC)
Cable to Luminaire
HT66 - XXX - XXX - DC
PWR-CLN-600-CC2800-381AL-MP230
PWR-CLN-600-CC2800-381AL-MP415
Cable glands not included.
Size: M25 x 1.5
OUT
IN
OPTIONAL
CONTROLS
FACTORY
CONNECTIONS
NOT TO BE
ALTERED
−
n/c
N
TC
N
TC
+
ACCESSORIES
Once the product has reached end of life, unit is to be disposed of in accordance to local e-waste laws or regulations. Do not dispose of these products as
unsorted municipal waste: take them for recycling. For information on your nearest recycling point, check with your local waste authority.
Distance between the power supply and luminaire can be extended up to 50 metres using a suitable extension loom.
See
ACCESSORIES
section for details.
If the NTC connection is not detected between the luminaire and power supply the power supply will operate in safe mode providing a 30%
power output. For optimal operation the wiring connections must be made according to the installation manual with the appropriate wire gauge.
KIT CONFIGURATION HT66-320
Luminaire
Cable = 2m
Power Supply
+
–
NTC
NTC
(Not Included)
230VAC IN
230VAC OUT
Optional
(Not Included)
Junction Box
(Not supplied)
Junction Box
(Not supplied)
Luminaire
Cable = 2m
Up to 50m
Cable Length
(Cable not supplied)
PART #
CBL-2C142C20-BKC-20
CBL-2C142C20-BKC-30
CBL-2C142C20-BKC-40
CBL-2C142C20-BKC-50
DESCRIPTION
Cable, 2C*14AWG, 2C*20AWG, Red, Black, White and Blue Conductors, Black Circular Jacket, 105°C 300V PVC/PVC, 8.5mm OD, 20 metres
Cable, 2C*14AWG, 2C*20AWG, Red, Black, White and Blue Conductors, Black Circular Jacket, 105°C 300V PVC/PVC, 8.5mm OD, 30 metres
Cable, 2C*14AWG, 2C*20AWG, Red, Black, White and Blue Conductors, Black Circular Jacket, 105°C 300V PVC/PVC, 8.5mm OD, 40 metres
Cable, 2C*14AWG, 2C*20AWG, Red, Black, White and Blue Conductors, Black Circular Jacket, 105°C 300V PVC/PVC, 8.5mm OD, 50 metres
Page 2 / 2
aus.
1300 287 533 •
intl.
+613 8681 3633 • www.coolon.com.au
Product must be installed by a suitably qualified person. All documentation is subject to change without notice. Refer to our website for the latest information.
www.coolon.com.au
Page 2 / 2
HT66 INDUSTRIAL LED LUMINAIRE
MANUAL
EDITION 2.0
Cable to Luminaire
HT66 - XXX - XXX - DC
Cable glands not included.
Size: M25 x 1.5
OPTIONAL
CONTROLS
FACTORY
CONNECTIONS
NOT TO BE
ALTERED
−
n/c
N
TC
N
TC
+
Junction Box
(Not supplied)
Luminaire
Cable = 2m
Up to 50m
Cable Length
(Cable not supplied)
(Cable not supplied)
Up to 50m Cable Length
230VAC nominal input voltage
415VAC nominal input voltage
Use any 2 phases and connect to
A
and
N
**Optional loop-out terminals
are not connected on the
control board. A wiring
connection must be made
from the input wiring terminal
to the loop out terminal where
optional loop out is required.
Cable from
Luminaire