Shenzhen Coolmay Technology Co.,Ltd
CX-WIFI-2NET module user manual
www.coolmay.com
Page
92
, Total 93 pages
conflict between dynamic allocation and statically assigned addresses.
Question 7: The WIFI module is connected to the PC (Server) as a data
acquisition card. How to set it?
As shown in the following figure, three modules establish three TCP
connections with the PC:
All three modules are used as data cards, the 1# module is used as the AP,
and the other two modules are connected to the 1# module WIFI.
The IP address of the PC is 10.10.100.100, which is TCP Server and port
8899.
1# module protocol setting: TCP Client, 10.10.100.100: 8899
2# module WAN IP is 10.10.100.101, protocol setting: TCP Client,
10.10.100.100:8899
3# module WAN IP is 10.10.100.102, protocol setting: TCP Client,
10.10.100.100: 8899
The 2# module LAN IP is changed to 10.10.99.254, and the 3# module
LAN IP is changed to 10.10.98.254 to avoid conflict.