C200H AC Servo Manual
81
7.2 P3 Group Parameters For Multifunctional Terminals
7.2.1 Parameter Table
C200H series driver has 8 input terminals and 6 output terminals. The terminal input and
output definition values can be changed through P3 group series parameters to complete various
input and output definitions. (the default low level of input terminal is valid).
Parameter
Name
Range
Default Value
P3-0
Digital Input DI1 Function
0-99
1
P3-1
Digital Input DI2 Function
0-99
2
P3-2
Digital Input DI3 Function
0-99
3
P3-3
Digital Input DI4 Function
0-99
4
P3-4
Digital Input DI5 Function
0-99
5
P3-5
Digital Input DI6 Function
0-99
6
P3-6
Digital Input DI7 Function
0-99
7
P3-7
Digital Input DI8 Function
0-99
8
P3-13
Low 8-bit current position value
-32768 - 32767
0
P3-14
High 8-bit current position value
-32768 - 32767
0
P3-15
Digital Input DI forced effective1
00000000-11111111
00000000
P3-16
Digital Input DI forced effective2
00000000-11111111
00000000
P3-17
Digital Input DI forced effective3
00000000-11111111
00000000
P3-18
Digital Input DI forced effective4
00000000-11111111
00000000
P3-19
Digital Input DI forced effective5
00000000-11111111
00000000
P3-20
Digital Output DO1 Function
0-99
18
P3-21
Digital Output DO2 Function
0-99
3
P3-22
Digital Output DO3 Function
0-99
5
P3-23
Digital Output DO4 Function
0-99
8
P3-24
Digital Output DO5 Function
0-99
6
P3-25
Digital Output DO6 Function
0-99
7
Содержание C200H Series
Страница 1: ...https en coolmay com ...
Страница 2: ...C200H AC Servo Manual https en coolmay com ...
Страница 43: ...C200H AC Servo Manual 36 Pic 4 17 Ground Connection Handling Of Noise Filter ...
Страница 52: ...C200H AC Servo Manual 45 5 2 2 Speed Mode Wiring 三相 Pic5 4 Speed Mode Wiring ...
Страница 55: ...C200H AC Servo Manual 48 5 3 2 Torque Mode Wiring Pic5 6 Torque Mode Wiring ...
Страница 64: ...C200H AC Servo Manual 57 No 4 alarm ...
Страница 119: ...C200H AC Servo Manual 112 Version 22 51 ...