115V(100Vmin.-120Vmax.),  

230V (200Vmin.-240Vmax.). 50Hz-60Hz.  

 
 

3.2 DC Output  

Power distribution configuration:  

 

Model 

                             ZX

-

5

00 

 

DC O/P Load 

Max. 

5

00W 

+3.3V 

2

0

+5V 

2

5

+12V1 

                                       

34

-12V 

0.

8

+5V

SB 

                                                            

3

A  

 

3.3 Protection  

The power supply itself is designed with short circuit, over voltage and over load 
protection functions described as below:  

 

3.3.1 Short Circuit Protection  

A short circuit on any DC output will cause the power to latch. The power  
supply  will  withstand  a  continuous  short  circuit  to  the  output  without  damage  or 
overseers  to  the  unit.  The  +5V

SB

  can  be  shorted  indefinitely  and  will  recover 

automatically when the short is removed.  

3.3.2 No Load Operation  

No hazardous conditions or damage to the supply will occur with all of the DC output 
connectors disconnected from the load.  

 
 
 
 