background image

 

115V  (100V  min.-132V  max.),  10A,  60Hz  

230V (200V min.-264V max.), 5.5A,50Hz  

 
 

3.2 DC Output  

Power distribution configuration:  

 
 

Model 

V-400 

+3.3V 

20A 

+5V 

18A 

+12V 

18A 

+12V2 

16A 

-12V 

0.5A 

+5V

SB 

2.5A 

3.3 Protection  

The power supply itself is designed with short circuit, over voltage and over load 
protection functions described as below:  

3.3.1 Short Circuit Protection  

A short circuit on any DC output will cause the power to latch. The power supply 
will withstand a continuous short circuit to the output without damage or overseers 
to the unit. The +5V

SB

 can be shorted indefinitely and will recover automatically when 

the short is removed.  

3.3.2 No Load Operation  

No hazardous conditions or damage to the supply will occur with all of the DC output 
connectors disconnected from the load.  

 
 
 
 

2  

Содержание V-400

Страница 1: ...is power supply to your precious computer tower Follow the steps below to finish the setup Step1 Open the computer tower cover put the power supply into the corresponding location of the tower and then use right screws to fix the power supply to tower Step2 Put the Main Power Connector ATX12V Connector S ATA Connector Peripheral Connectors and Floppy Connectors to the corresponding male connectors...

Страница 2: ...ion functions described as below 3 3 1 Short Circuit Protection A short circuit on any DC output will cause the power to latch The power supply will withstand a continuous short circuit to the output without damage or overseers to the unit The 5VSB can be shorted indefinitely and will recover automatically when the short is removed 3 3 2 No Load Operation No hazardous conditions or damage to the s...

Страница 3: ...ed Load 10 90 RH 20C 80C 80 Rated Load Storage 20C 80C 5 90 RH No degradation of the power supply shall occur during shipping or storage at the specified condition 3 5 Regulatory Compliance Our power supply has been certified to comply with multi national Safety and EMI UL CUL CSA TUV FCC CB 4 Precaution Caution Unauthorized personnel should not do this to avoid electrical shock 4 1 Do not open th...

Страница 4: ... output connectors plugging in proper direction and connecting firmly 5 4 Please turn off the power and turn it on for several times and the interval must be at least 5 seconds 5 5 Having checked above items if the power supply still does not function please send it back to your retailer or distributor for repair ...

Отзывы: