background image

3

3.3.3 Over Load Protection

3.4 Physical Environment

Operation Conditions

When the total load exceed 130%~160% of the maximum output current, the
power supply shall be latched into the state of shutdown.

The power supply shall be capable of continuous operation and meet all
electrical specification without need for adjustment when subjected to the
following environmental conditions:

Temp. Vs Load Condition

Humidity

Operation

Storage

-20°C ~80°C

10%~90%RH

5%~90%RH

No degradation of the power supply shall occur during shipping or storage at the
specified condition.

Our power supply has been certified to comply with multi-national Safety and EMI.
-- UL, CUL, CSA, TUV, FCC

4.1 Do not open the top cover of the power supply case.

4.2 Please keep the power supply from humidity.

3.5 Regulatory Compliance

Caution: Unauthorized personnel should not do this to avoid electrical shock!

4. Precaution

0 ~30°C@Full Load

40°C@90%Rated Load

50°C@80%Rated Load

If power supply cannot work properly, before send for repair, please check the
following items:

5.1 Does power cord indeed plug into electrical outlet?
5.2 Does Input Voltage set in power supply correspond to the main source in 
      your environment?
5.3 Please check the output connectors plugging in proper direction and connecting firmly.
5.4 Please turn off the power and turn it on for several times, and the interval must
      be at least 5 seconds.
5.5 Having checked above items, if the power supply still does not function, please
      send it back to your retailer or distributor for repair.

5. Simple Maintenance

Содержание NW-450B

Страница 1: ...Table of Content 1 Function Description 2 How to Setup 3 Specifications 4 Precaution 5 Simple Maintainance 6 Mechanical Diagram 1 1 1 3 3 3 4 ...

Страница 2: ... PCI Express Conntector and many others when available to the corresponding male sockets such as main board peripheral devices i e HDD CDROM etc and floppy drivers respectively When you connect connectors please pay attention to the orientation of them because of the different hole sizes Find the proper orientation and push down firmly making sure that the pins are aligned 2 How to Setup 1 Full Ra...

Страница 3: ... 3 1 Short Circuit Protection 3 3 2 No Load Operation A short circuit on any DC output will cause the power to latch The power supply will withstand a continuous short circuit to the output without damage or overseers to the unit The 5VSB can be shorted indefinitely and will recover automatically when the short is removed No hazardous conditions or damage to the supply will occur with all of the D...

Страница 4: ... Do not open the top cover of the power supply case 4 2 Please keep the power supply from humidity 3 5 Regulatory Compliance Caution Unauthorized personnel should not do this to avoid electrical shock 4 Precaution 0 30 C Full Load 40 C 90 Rated Load 50 C 80 Rated Load If power supply cannot work properly before send for repair please check the following items 5 1 Does power cord indeed plug into e...

Страница 5: ...4 6 Mechanical Diagram NW 450B ...