Remind Message
Warning
code
malfuncti
on
Possible cause
Suggested remedy
F3
Fan over
current
Internal fault
Turn off the device for at
least 5 minutes, then
restart it. If the problem
persists, you need to
authorize a repair center
to inspect it.
F4
Compress
or start
failure
system is high than 5
bar
/
F5
Compress
or speed
is low
The ambient
temperature is too
high
Turn off the device for at
least 30 minutes, or move
to a colder location, and
then restart.
F6
Controller
over
temperatu
re
If the refrigeration
system has been too
heavily loaded,or if
the ambient
temperature is higher
than 55°C
,
the
controller will run too
hot
/
Blocked vents or
insufficient clearance
around
Clear the vents and leave
enough clearance with
the surroundings
Internal fault
Authorized repair center
inspection
F1
NTC open
Internal fault
Need to be inspected by
an authorized repair
center
F1
NTC short
circuit
/
/
F1
Switch
error
/
Turn off the device for at
least 1 minute, and then
restart it. If the problem
persists, you need to
authorize a repair center
to inspect it.
F1
Communi
cation
error
/
19