 CAUSE

REMEDY

PROBLEM - Unpleasant Odour

Odour from new pads.

1.

Allow time to condition by running the
cooler.

 

CAUSE

REMEDY

PROBLEM - Inadequate Cooling

1.

Dry pads.

2.

Check water flow to pads.
Ensure water supply is turned on.

TROUBLESHOO

TROUBLESHOO

TROUBLESHOO

TROUBLESHOO

TROUBLESHOOTING GUIDE

TING GUIDE

TING GUIDE

TING GUIDE

TING GUIDE

Insufficient exhaust openings for
conditioned air.

Ensure sufficient openings. Refer to chart
on page 2.

3.

Excessive ambient humidity.
( See also insufficient exhaust.)

On days during the summer when the
ambient humidity is high, the cooler will
not reduce the temperature as much as
on drier days.

If your thermostat display flashes “Service” or should you consider that your
cooler requires service, you should contact your local Dealer or the War-
ranty Service number shown on the back cover.

When you contact your Dealer regarding service or warranty please quote
the unit model number and serial number as shown below.

Model No.

_____________________ Serial No. _____________________

Содержание CPL1000

Страница 1: ...C P L S E R I E S OWNER S ...

Страница 2: ...2 2 2 2 2 Introduction Thermostat Functions Standard Bleed System and Drain Valve Maintenance Troubleshooting CONTENTS CONTENTS CONTENTS CONTENTS CONTENTS Page 2 Page 3 Page 7 Page 8 Page 10 ...

Страница 3: ...er is built from the highest quality materials and engineered to provide many years of economical trouble free cooling Please take a few minutes to read these in structions so you have a full understanding of how to operate your cooler Your installer should demonstrate the features and proce dures set out in these instructions The in staller should also provide you with a Model and Serial number w...

Страница 4: ...een operated for a while then when you start it Pre Cool Cycle may sometimes flash on the display as shown This indicates that the water pump will oper ate to saturate the cooling pads for a few min utes before the fan is turned on This is to ensure that when the fan starts only cool air enters your home STARTING YOUR COOLER THERMOST THERMOST THERMOST THERMOST THERMOSTA A A A AT FUNCTIONS T FUNCTI...

Страница 5: ... will cir culate through your home AUTOMATIC MODE The AUTO button switches between Automatic mode and Manual mode When Auto is dis played the cooler is under Automatic control and will operate according to the temperature sensed at the thermostat When the cooler is turned on it will read the temperature and set the cooler operation ac cordingly If the temperature increases at the thermostat then t...

Страница 6: ...rt time press TIMER TIMER TIMER TIMER TIMER with the cooler turned OFF Starting in will be displayed as shown with the last mode of operation Manual or Automatic 2 If you want the cooler to turn on in Auto matic mode with the previous settings then press A A A A AUT UT UT UT UTO O O O O until Auto is displayed Alter natively if you want the cooler to turn on in Manual mode press A A A A AUT UT UT ...

Страница 7: ...atic mode you are not cool enough Simply press to increase the cooling rate Now that you have read these instructions press ON OFF ON OFF ON OFF ON OFF ON OFF to turn your cooler on If the cooler has not operated for a while Pre Cool Cycle will flash on the display The Pre Cool Cycle will begin and will take only a few min utes to complete After this time the fan will come on automatically and you...

Страница 8: ... optional automatic drain valve If the drain valve was installed instead of the standard bleed system then your cooler will au tomatically drain after a set time of continuous operation This ensures the water is always fresh and helps maintain your cooler in good condi tion to ensure optimum cooling performance The frequency of the automatic drain may have been adjusted by your installer according...

Страница 9: ... coverage WARNING END OF SEASON SERVICE Please note that some State regulations re quire evaporative air coolers to be serviced at specific intervals HEALTH REGULATIONS Turn off the power supply to the cooler Turn off the water supply to the cooler Remove the pad frames as shown Turn off the power switch inside the cooler Check and clean water channels in the lid If fitted first unclip and then re...

Страница 10: ...is fitted If fitted with a drain valve this will not be necessary as it will automatically close when the cooler is turned on Turn on the power switch inside the cooler Turn on the water and then the power Re fit the pad frames and run the cooler PRE SEASON SERVICE Take hold of the pad frame and pull it towards you until the internal side clips disengage To remove a pad frame insert a flat screw d...

Страница 11: ...cient openings Refer to chart on page 2 3 Excessive ambient humidity See also insufficient exhaust On days during the summer when the ambient humidity is high the cooler will not reduce the temperature as much as on drier days If your thermostat display flashes Service or should you consider that your cooler requires service you should contact your local Dealer or the War ranty Service number show...

Страница 12: ...C P L S E R I E S 834962 D 0601 ...

Отзывы: