9
6.2 Repair procedures
Repairs should be performed by a qualified technician!
ELECTRICAL SHOCK HAZARD
Disconnect the power supply before performing any service or maintenance on the unit. Failure
to do so may result in serious injury or death.
BLIZZARD (CS6-50-VD) Fan Motor Replacement
1. Remove cap from bottom of motor. Disconnect wires. Clip wire ties.
2. Remove (4)
fan mounting bolts from the front. (Support fan to ensure it doesn’t fall.)
3. Pull the fan out of the unit.
4. Remove blade mounting nut and blade.
5. Remove mounting arms by loosening (8) bolts holding the arms to the motor. (Make
note of arms positions for reinstallation.)
6. Install arms and blade on new motor.
7. Install fan in opening and secure with mounting bolts.
8. Reconnect wires and tie cord to motor arm to keep them out of fan.
Pump Replacement
1. Disconnect hose from pump.
2. Unplug the cord from the top of the pump by removing (2) screws
3. Remove pump from water sump and install new pump.
4. Reverse the above procedures to reconnect the wiring, lift pump bracket and reconnect
the hose. Secure wires to fan frame with wire ties to clear the fan blades. Be sure to
position the plug correctly.
5. Reinstall cooling pads and guards, reconnect power and test pump.
6.3 Technical support
Technical support and service are available directly from your distributor or
COOL-
SPACE
®
Technical Support Line at 1-800-557-5716
Visit: www.cool-space.com
Email: [email protected]