SPECIFICATIONS 

x

The cooling capacity is measured at an ambient temperature of DB 86 °F, WB 78 °F. 

x

Noise level is measured at a distance of 3.28 ft away from the front of the unit, when the unit is in cooling mode.

x

Power consumption is measured when the fan runs at the highest speed setting. 

x

These specifications are for reference only. For actual data, please refer to the rating label on the back of the unit. 

x

If the environment temperature is higher than the max operating temperature or lower than the minimum operating 

temperature, the air conditioner may not work properly. 

x

Dehumidifier mode works when ambient temperatures are between 61°F - 86°F 

x

Air Conditioner mode operates up to an ambient temperature of 95

°

F.

PACKAGE CONTENTS 

Portable Air Conditioner 
Exhaust Hose (1) 
Front Exhaust Hose Adapter (1) 
Window Kit Adapter (1) 
Rear Exhaust Hose Adapter (1) 
Remote Control & AAA Batteries (2 batteries) 
Window Kit - 3 Sliding Panels (1 single hose panel, 2 extension panels) 
Owner’s Manual 

Model 

CL-PAC-121

CL-PAC-122 (with Heat) 

Power Supply (Ph/V/Hz) 

1/115/60Hz 

1/115/60Hz 

Dehumidifying Capacity (Pints/Day) 

81.6 

81.6 

Rated Cooling Capacity (BTU/h) 

12,000 

12,000 

Rated Heating Capacity (BTU/h) 

-

10,500 

Cooling Power Input (Watts) 

1465 

1465 

Heating Power Input (Watts) 

-

1200 

Rated Current Cooling (Amperage) 

13 

13 

Rated Current Heating (Amperage) 

-

10.6 

Noise Level (dBA) - H/M/L 

55/53/51 

55/53/51 

Air Flow - H/M/L (CFM) 

235/205/175 

235/205/175 

Product Dimensions (W

 x H

 x D

17.75 x 33.125 x 17.125 

17.75 x 33.125 x 17.125 

Product Weight (Lbs) 

80 

80 

Refrigerant Type 

R-410A 

R-410A 

PROBLEM

   

 

The Air Conditioner will not start

POSSIBLE CAUSES 

The air conditioner is unplugged or not 

connected well. 

The fuse is blown/circuit breaker is 

tripped.

Power Failure 

The current interrupter device is 

tripped.

SOLUTIONS

x

Make sure the air conditioner plug 

is pushed completely into the out-

let

x

Check the house fuse/circuit 

breaker box and replace the fuse 

or reset the breaker. 

x

The unit will automatically re-start 

when power is restored. 

x

There is a protective time delay 

(approx. 3 minutes) to prevent  

tripping of the compressor      

overload. For this reason, the unit 

may not start normal cooling for 3 

minutes after it is turned back on. 

x

Press the RESET button located 

on the power cord plug. 

x

If the RESET button will not stay 

engaged, discontinue use of the 

air conditioner and contact a   

qualified service technician.

TROUBLESHOOTING

The Air Conditioner does not cool 

as it should 

 

The Dehumidifier function is not 

providing cool air as it should 

Airflow is restricted 

The temperature control may not be 

set correctly. 

The air filter is dirty 

The room may be too warm 

Cold air is escaping 

The Evaporator is frozen 

x

Make sure there are no curtains, 

blinds, or furniture blocking the 

front of the air conditioner 

x

Lower the set thermostat tempera-

ture

x

Clean the filter. See the Cleaning 

and Care Section of the manual. 

x

Please allow time for the room to 

cool down after turning on the air 

conditioner.

x

Check for open furnace registers 

and cold air returns

x

The unit is defrosting and will re-

sume operation when done. 

The Air Conditioner displays the 

Timer hours but does not work 

Is the TIMER ON enabled? 

x

Cancel the TIMER or wait until the 

unit turns on. 

The Remote Control is not working 

The batteries are inserted incorrectly 

The batteries may be dead 

x

Check the position of the batteries.    

x

Replace the batteries 

 14 

Содержание CL-PAC121

Страница 1: ...nted in Mexico SC 06 06 14 BPN NA Pags 8 SHN model CL PAC121_CL PAC122 804105214 Please read instructions carefully before operating the unit Models CL PAC 121 CL PAC 122 12 000 BTU Portable Air Conditioner OPERATING INSTRUCTIONS ...

Страница 2: ...o not start or stop the unit by insertingor pulling out the power plug 6 Do not use an adapter plug or extension cord 7 Do not use the unit in the immediate surroundings of a bath a shower or a swimming pool 8 Do not insert anything into the air outlet Do not obstruct air inlet or outlet grills unless instructed by this manual 9 Do not let children play near this unit 10 Always inspect the cord fo...

Страница 3: ...ot start POSSIBLE CAUSES The air conditioner is unplugged or not connected well The fuse is blown circuit breaker is tripped Power Failure The current interrupter device is tripped SOLUTIONS x Make sure the air conditioner plug is pushed completely into the out let x Check the house fuse circuit breaker box and replace the fuse or reset the breaker x The unit will automatically re start when power...

Страница 4: ... 2 The TEST and RESET buttons should not be used as ĀONā and ĀOFFā switches 3 The cord and plug are not intended to offer protection to externally connected loads or supply circuits 4 The cord and plug are intended for indoor use only RESET TEST 4 MAINTENANCE Note Make sure power is off and the power cord is not plugged into an electrical outlet prior to performing any maintenance on the unit Clea...

Страница 5: ...ss and buttons together at the same time to lock the remote keyboard Do this again to unlock AUTO AUTO MODE x Press the MODE button to select Auto Mode Once Auto Mode is selected the unit will automatically choose the operating mode based on the current room temperature The temperature will not be displayed on the LED in this mode TEMP MEASURE CHANGE BETWEEN F and C x Whentheunitis off press the M...

Страница 6: ...more to savethe setting Press the ON OFFbuttonto clear a time setting Press the Save button to automatically rotate through the different speeds To disable Save mode and pick your own fan speed press the Save button again Press theHorizontal SwingButton toturnonand off the Horizontalswingmode Inhorizontalswingmode the louvers will rotate left andright tocirculatemore air Press the Left and Right S...

Страница 7: ...pressingthe Upand DownSwingButton and button at the sametime TheSwing Icononthe Remote LCDwill blink twice whenthis isdisabled REMOTE CONTROL MODE MODE BUTTON ON OFF ON OFF BUTTON FAN FAN BUTTON BUTTONS TEMP BUTTON AUTO COOL DRY FAN HEAT Low Speed Medium Speed High Speed SIGNAL TRANSMITTER REMOTE CONTROL OPERATING INSTRUCTIONS 7 When the unit is in Air Conditioner or Heater CL PAC 122 mode you can...

Страница 8: ...d window kit must be installed when the unit is in Air Conditioner Dehumidifier DRY or Heater CL PAC 122 only mode When using the unit as a fan it is not necessary to keep the exhaust hose and window kit connected to the unit 3 Temperature Select the desired temperature by pressing either źorŸ key when using the unit in Cooling or Heating CL PAC 122 only mode The digital thermostat will display th...

Отзывы: