GENERAL INFORMATION 

Applicable to all controller types 

• 

If the unit appears to surge at times, check that strong wind drafts are not the cause. A strong 
gust of wind may cause the fan to race momentarily as it is ‘wind assisted’. 

• 

At times of high humidity, cooling performance is diminished.  Operate the fan only. 

• 

The cooling ability of a system is not only related to the efficiency of the unit design, but also to 
the duct design and professional installation. Insulated ceilings will lower internal temperatures 
significantly over non-insulated ceilings. 

• 

During operation in Cool Mode,  water discharges from the overflow pipe.   This water has been  
re-circulated through the pads many times.  The evaporation process results in a build-up of 
minerals and solids in the water. This water, if channelled onto the garden may be harmful to 
some plants. It is not suitable for animal or human consumption.  Test the water on plants in 
small amounts before fully discharging into the garden. 

• 

Never operate the system if the room vents have been closed off. This may cause overheating 
and damage to the motor.  

• 

At the time of initial start-up an odour may be detected.  This odour is characteristic of Celdek 
filter pads.  It is neither harmful nor particularly unpleasant and will dissipate within 2-3 days.  
The fan motor may also have an ‘electrical’ type smell for a short period as it heats up initially, 
and residual varnish is ‘burnt off’ the motor’s surface. 

• 

When the COOL mode commences, the tank is filled with water.  This takes approximately 90 
seconds, during which time the pump remains switched off.  When the pump starts, water is 
pumped up into the Celdek pads which quickly lowers the water level.  For a short period of up to 
one minute the water being pumped up into the filter pads exceeds the amount of fresh water 
flowing into the base.  The pump may make an intermittent “slurping” noise until the water level 
is balanced.  This is not harmful to the pump nor always audible, but please be aware of it 
should you hear it. 

PRE SEASON MAINTENANCE 

We recommend an annual service, to keep your system in top operating condition.   

The Service Centre telephone number together with the unit size and serial number are recorded on 
the front and back of this guide. Electrical components to be maintained by qualified service people.

 

1. 

Isolate power at property’s main supply board.  Disconnect 
unit’s’ power plug from the mains supply.  If cable damaged 
have it replaced by qualified person. 

2. 

Remove the lid. 

3. 

If necessary, clean the base. 

4. 

Close the water shut-off valve. Remove and clean shut-off 
valve filter.  Open shut-off valve. 

6. 

Turn on the power. Operate the system in COOL Mode,     
check that the drain valve closes and the tank fills with water. 

7. 

Adjust the water level if necessary. Ideally this level should be 
10mm below the overflow. 

8. 

Check that the water is being evenly distributed over the pads 
and that there are no  obstructions in the water distributor, 
located above the pads. 

9. 

Replace the lid and secure it by firmly tightening the lid bolts.  
Do not over-tighten. 

SHUT-OFF VALVE & FILTER

 

Содержание QA CONTROLLER

Страница 1: ...wing Is the power connected Is the water supply to the unit turned on at the isolator tap For service calls attended during the warranty period 1 Provide the service person with proof of purchase ie Invoice from installing dealer 2 Where no fault has been found service charges will be payable at the standard service rate NOTE The air conditioning system is to be operated by a responsible adult or ...

Страница 2: ...t being cooled EXHAUST Operates in EXHAUST Mode with each outlet acting as an extraction fan No direct cooling is possible in this mode OFF Switches off and cancels any un elapsed time in the TIMER Mode TIMER A count down timer to switch the system on or off AUTO Switches to AUTO Temperature Mode Fan speed and water are regulated automatically according to the set temperature 1 Dims or brightens t...

Страница 3: ...15 minutes to complete The FLUSH cycle can be stopped sooner than 15 minutes by pressing FAN before OFF FAN The FAN mode is useful when the outside ambient temperature has dropped and no direct cooling is required EXHAUST A delay occurs when switching to EXHAUST mode This protects the motor and allows it time to stop before the rotation is reversed Exhaust mode is useful for expelling odours from ...

Страница 4: ...once the Timer period has elapsed The temperature displayed is accurate for the purpose of operating the AUTO feature of your air conditioning system Do not obstruct the ventilation slots in the keypad base as this may cause an incorrect temperature reading BUSHFIRE MODE This mode is activated by pushing the COOL button twice The fan remains off so that smoke will not be introduced into the house ...

Страница 5: ...on the keypad to change This process may need to be repeated several times before the desire temperature is attained Once the temperature is set replace the keypad cover LOCATING THE TEMPERATURE SENSOR POT Remove the outer cover from the keypad as shown in the picture The temperature sensor pot is located on the right hand side of the keypad 15mm from the lower edge Side view of keypad showing the...

Страница 6: ...n EXHAUST Mode with each room outlet acting as an extraction fan No direct cooling is possible in this mode OFF Switches Off FAN SPEED Fan speed indicator lights FLASHING LED One of the function LED s flashes during a housekeeping cycle or wait time 1 Adjusts fan speed 2 Dims or brightens the LED indicators when the system is in OFF mode COOL FAN EXHAUST OFF FAN SPEED ...

Страница 7: ...n 15 minutes by pressing FAN then OFF FAN The FAN Mode is useful when the outside ambient temperature has dropped and no direct cooling is required EXHAUST A delay occurs when switching to EXHAUST Mode This is to protect the motor and allow it time to stop before the rotation is reversed Exhaust mode is useful for eliminating odours from the home without the in rush of air experienced with the COO...

Страница 8: ...face When the COOL mode commences the tank is filled with water This takes approximately 90 seconds during which time the pump remains switched off When the pump starts water is pumped up into the Celdek pads which quickly lowers the water level For a short period of up to one minute the water being pumped up into the filter pads exceeds the amount of fresh water flowing into the base The pump may...

Страница 9: ... principle By closing the window of an unused room the air will exit through the door channelling the air to other rooms It is usual to install outlets away from windows Opening a window will allow the air to pass through the room and cool it By closing all windows and opening the door the air will exit directly through the door For persons not wishing to leave doors and windows open particularly ...

Страница 10: ... Date ____ ____ ____ INSTALLER PLEASE CONFIRM TICK Serial Number __________________ 1 Water level checked adjusted if required Number of Units on site ___________ 2 Weather seal if fitted operating freely 3 Operation of system explained to customer CONDITIONS OF WARRANTY AUSTRALIA OWNER PLEASE MAKE SURE THAT THIS FORM HAS BEEN FULLY COMPLETED BY YOUR DEALER FOR INSTALLATIONS OUTSIDE AUSTRALIA CONT...

Страница 11: ...loat level adjustment where applicable cleaning of filters Celdek pads cleaning of water distributor scale or build up caused by poor water quality The express warranties contained herein are in lieu of all other warranties Implied warranties including warranties or merchantability are limited to the duration of the complete unit warranty described herein Consequential or incidental damages for th...

Страница 12: ...FM2514 0110 ...

Отзывы: