2) Check the Battery voltage first.
- Minimum 7 Volts. Replace battery if voltage is at or below minimum.
DIP SWITCH CONFIGURATIONS
RECEIVER SWITCH SETTINGS
1
2
3
4
5
ON
OFF (0)
OFF (0)
ON
5
4
3
2
1
TRANSMITTER SWITCH SETTINGS
6
7
8
TROUBLESHOOTING
1) Verify address selection dip switches (1 thru 4) are set the same on the Transmitter and Receiver.
ADDRESS
SELECTOR
SELECTOR
ADDRESS
FACTORY SET
DO NOT ADJUST
6
Open door several feet - Verify that unit is still in "Supervised Mode". Constant
3)
Reconnect sensing edge to Transmitter.
4)
Unit will switch to "Normal Mode".
- (D6) "Normal Mode" (GRN) LED will light. Door now requires momentary
contact for CLOSE control.
pressure required on door CLOSE control.
ON (1)
TEST
MODE
ON (2 WIRE, 10K TERMINATION EDGE)
3) Make sure the antenna is attached to the receiver, and that the "tip" of the antenna is NOT aimed
OFF (4 WIRE EDGE)
at the transmitter (the side of the whip antenna is what picks up the signals, not the tip).
4) Do NOT mount the antenna inside a closed metal box; the box will shield the antenna from all
signals, and the receiver will not work as a result. If the receiver must be mounted inside a metal
box, use an antenna extension kit to mount the antenna on the outside of the metal box.
5) Make sure the transmitter is mounted so that when the door is partly open, you are looking
directly at the label on the lid and not looking at the side of the case.