electrical requirements
Any permanent electrical installation must comply with the latest I.E.E.
Regulations and local electricity company regulations. for your own safety a
qualified electrician or contractor who is on the roll of the National Inspection
Council for Electrical Installation Contracting (NICEIC) should undertake the
electrical installation.
electrical connection
Before connecting the mains supply ensure that the mains voltage corresponds to
the voltage on the rating plate inside
wArning: thiS APPliAnce mUSt Be eArtheD
The appliance is supplied with a 3-core mains cable and must be connected to the
electricity supply via a double pole switch having a 3mm minimum contact gap on
each connector.
for UK only
A Switched fused Connection Unit to BS 1363 Part 4 is
recommended.
the fuse must be rated at 32 Amps.
The wires in the mains lead are coloured in accordance with the following code:
Brown = l - live
Blue = n - neutral
green and Yellow = - earth
The connection point must be placed in a position adjacent to the appliance so as
to be readily accessible for an engineer in the event of a breakdown.