Cooke & Lewis IHB40CL Скачать руководство пользователя страница 17

17

In

 more 

detail...

IHB40CL 

42cm Box Island Hood

GB

IE

Technical and legal information

Wiring

All installation work must be carried out by a competent 

Before connecting the mains supply ensure that the mains 

voltage corresponds to the voltage on the rating plate.

WARNING: THIS APPLIANCE MUST BE EARTHED.

Mains Supply could be connected to the Mains Voltage by Direct Connection

USE A 3AMP FUSE

DOUBLE POLE SWITCHED

FUSED SPUR OUTLET

FUSE ON

EUR

UK

Direct Connection

If the appliance is being connected directly to the mains an omnipolar circuit-

breaker must be installed with a minimum opening of 3mm between contacts.

The installer must ensure that the correct electrical connection has been made 

and that it complies with wiring diagram.

The cable must not be bent or compressed.

Regularly check the power plug and power cord for damage. If the supply cord is 

damaged, it must be replaced by a special cord or assembly available from the 

manufacturer or its service agent.

Содержание IHB40CL

Страница 1: ...42cm Box Island Hood IHB40CL Version 03 GB IE 42cm Box Island Hood Barcode 5052931258697 WARNING Read the instructions before using the appliance...

Страница 2: ......

Страница 3: ...01 x 1 02 x 1 03 x 1 IHB40CL 42cm Box Island Hood 04 x 12 3 5 x 9 5mm 1 1...

Страница 4: ...for future reference Getting started 04 Your product 05 Before you start 05 Safety 06 In more detail 11 Operation 11 Care and maintenance 13 Troubleshooting 15 Recycling and disposal 16 Technical and...

Страница 5: ...unpacking the cooker hood please check that it is not damaged If in doubt do not use the appliance but contact Customer Services on 0344 800 1128 UK 0144 75261 Ireland Check the package and make sure...

Страница 6: ...6 UK IE 150mm VENT PACK 2 UK IE SELF ADHESIVE ALUMINIUM TAPE Safety These instructions are for your safety Please read through them thoroughly prior to installation and retain them for future referenc...

Страница 7: ...he reach of babies and small children This appliance can be used by children aged from 8 years and above and persons with reduced physical sensory or mental capabilities or lack of experience and know...

Страница 8: ...not caught under or in the appliance and avoid damage to the power cable Do not install the appliance outdoors in a damp place or in an area which may be prone to water leaks such as under or near a...

Страница 9: ...with the local authorities Make sure the maximum air room does not exceed 4 Pa 0 04 mbar The room must have adequate ventilation if an extractor hood is used simultaneously with appliances that run o...

Страница 10: ...od if it shows signs of damage or imperfection Contact customer services Flambe cooking must not be carried out underneath this appliance When installing the appliance make sure that the following dis...

Страница 11: ...part of the hood and includes Filter cleaning alert indicator switch Icon with a single press Clock setting Press to turn on the LED display and then press for 3 seconds the clock will be on and the...

Страница 12: ...on and off Press to turn on alarm and the minute time and to adjust the minute time press and after 3 seconds The max setting time is 9 59 Press for 3 seconds can cancel the alarm setting Lighting on...

Страница 13: ...ce OFF Warning always switch off the electricity supply before carrying out maintenance work on the hood In the event of a fault contact customer services FUSE 1 X ACTIVE CHARCOAL FILTER NOT SUPPLIED...

Страница 14: ...more detail IHB40CL 42cm Box Island Hood GB IE Use non corrosive liquid detergent or a stainless steel cleaner 1 MONTH MAX 65 C replace every 3 months 3 MONTHS Important manufacturer Care and mainten...

Страница 15: ...fter running for a while motor stop working High temperature safety device activated the manufactures instructions Distance between the cooker hood and the hob is too small Readjust the distance to Ga...

Страница 16: ...ctronic equipment collection point for recycling On ensuring that this product is disposed of correctly you will help to avoid possible negative consequences for the environment and public health whic...

Страница 17: ...MP FUSE DOUBLE POLE SWITCHED FUSED SPUR OUTLET FUSE ON EUR UK Direct Connection If the appliance is being connected directly to the mains an omnipolar circuit breaker must be installed with a minimum...

Страница 18: ...e mains supply ensure that the mains voltage corresponds to the voltage on the rating plate inside the appliance WARNING THIS APPLIANCE MUST BE EARTHED The appliance is supplied with a 3 core mains ca...

Страница 19: ...fter an appliance has been repaired or replaced any remaining balance of the GAA guarantee will be valid and any further call outs during this prescribed period will be covered by GAA on the replaceme...

Страница 20: ...is found then GAA reserves the right to charge for the call out at the going rate In the course of the service work carried out it may be necessary to remove the tiled in such a manner that it cannot...

Страница 21: ...onal law Standard EN 60335 1 Safety of household and similar electrical appliances Standard EN 60335 part 2 31 particular requirements for range hoods Standard EN 55014 Limits and methods of measureme...

Страница 22: ...22 Installation 01 You can choose two type of installation Ducted option Recirculation option DUCTED OPTION RECIRCULATION OPTION VENT PACK 2 UK IE CARBFILT 6 UK IE...

Страница 23: ...23 02 03 Mark and drill four holes of suitable diameter on the ceiling according to the dimensions shown Min 750 mm from gas cooker Min 650 mm from electric cooker DIM A 220 278 278 220 Front...

Страница 24: ...24 04 05 Fix the vent pack 2 using self adhesive aluminium tape Vent Pack 2 UK IE x 1...

Страница 25: ...25 06 07 Fix the upper and lower part of bracket together at the required length using eight screws Fix the upper decorative chimney to the upper part of bracket using four screws 04 x 8 04 x 4 04 04...

Страница 26: ...26 08...

Страница 27: ...actor f 1 5 Fluid Dynamic Efficiency FDEhood 12 9 Energy Efficiency Index EEIhood 81 8 Measured air flow rate at best efficiency point QBEP 278 5 m 3 h Measured air pressure at best efficiency point P...

Страница 28: ...GB IE B Q plc Chandlers Ford Hants SO53 3LE United Kingdom www diy com...

Отзывы: