Please read these instructions fully and completely before initial 

commissioning; they contain information for the correct installation 
of this innovative radio smoke alarm.

 

 
 
 

 
 

 
 

 
 
 

 
 

 
 

 
 

 
 
 
 

 
 

 
 

 
 

 
 
 
 

 
 

 
 

 
© 2003 Convia GmbH, Germany  

 
All rights reserved. This handbook must not be reproduced in any form, even in excerpts, or 
duplicated or processed using electronic, mechanical or chemical procedures without written 
permission of the publisher. This handbook may contain  mistakes and printing errors. The 

information in this handbook is regularly checked  and corrections made in the next issue. 
We accept no liability for technical mistakes  or printing errors, or their consequences. All 

trademarks and patents are acknowledged. 
 

Modifications due to technical improvements may be made without prior notification 
 

Please report manual-errors to [email protected]

 

Содержание HOMEGUARD MS8000

Страница 1: ... Smoke Detector Type 3 Operating Instructions Version 1 2 For Marmitek alarm installations of the types Homeguard MS8000 Security Systems MS9470 MS9480 Security Systems MS9770 MS9780 Base Stations SC2700 SC2800 ...

Страница 2: ...ocessed using electronic mechanical or chemical procedures without written permission of the publisher This handbook may contain mistakes and printing errors The information in this handbook is regularly checked and corrections made in the next issue We accept no liability for technical mistakes or printing errors or their consequences All trademarks and patents are acknowledged Modifications due ...

Страница 3: ...nces 5 4 Installation places 5 5 Installation 8 6 Registering the smoke detector with the base systems stations of the types MS9470 MS9770 MS9480 MS9780 SC2700 SC2800 10 7 Registering the smoke detector with the base station of the type Homeguard MS8000 11 8 Final assembly 12 9 Convia smoke detector technical data 12 ...

Страница 4: ... causes the light to be dispersed by smoke particles and picked up by the receiver In contrast to many products on the market no radioactive substance is necessary for the optical smoke detection The smoke detector will impress you owing to the following features Monitoring of rooms for the development of smoke Integrated signal transmitter Alarm transmission even for non activated alarm unit 2 In...

Страница 5: ...detectors should be installed in accordance with the NFPA Standard 74 National Fire Protection Association Batterymarch Park Quincy MA 02169 In principle it is advisable to install several smoke detectors in the building and or in the dwelling In any case at least one smoke detector should be installed in each floor of buildings with more than one floor Only like that a punctual and thus effective...

Страница 6: ...Page 6 of 12 Recommended best and acceptable locations to mount smoke detectors Locations for placing smoke detectors for single residence with only one sleeping area ...

Страница 7: ...Page 7 of 12 Locations for placing smoke detectors for single floor residence with more than one sleeping area Arrangement in a building with many floors ...

Страница 8: ...rates Ensure that the smoke detector is not installed directly on or in the vicinity of large metal objects as they can affect the radio range 5 Installation Please follow these steps to install the Convia smoke detector At the place where you are going to install the detector draw a horizontal line six inches long Remove the mounting bracket from your unit by rotating it counterclockwise Place th...

Страница 9: ...l outward on the detector to make sure it is securely attached to the mounting bracket Do not insert the battery at this stage 9V Please follow the steps of the next chapter before you insert the battery How to install the battery The smoke detector requires an alkaline battery Match terminals on the end s of the battery with opposite terminal connectors on the detector Be sure to insert the alkal...

Страница 10: ...est button on the detector to trigger the alarm The smoke alarm sends a radio signal to the base station The LED on the sensor illuminates briefly the base station emits a short signal tone as confirmation of reception 4 If you are using more than one smoke detector you have to follow these steps only once 5 Reset the mode switch to the RUN1 or RUN2 position Zone indicators go out Now the smoke de...

Страница 11: ...Place the battery 9V in the correct polarity in the battery holder of the smoke detector The smoke alarm sends a radio signal to the base station The LED on the sensor illuminates briefly the base station emits a short signal tone as confirmation of reception 5 If you are using more than one smoke detector you have to follow these steps only once 6 Press the 1 key again to leave the learning mode ...

Страница 12: ...al data Frequency 433 92 MHz Modulation AM Range Up to 30 meters Free field In combination with Homeguard the range is reduced Alarm 85 dB Power supply 9V Blockbattery Alkaline Type Operating temperature 10 to 45 degrees Celsius Air moisture 95 rel air moisture 2003 Convia GmbH Burgemeisterstr 34 12103 Berlin GERMANY http www convia gmbh de Please report manual errors to manual convia gmbh de ...