RECESSING THE INSERT

If the recess is to extend to the ceiling, a heat shield must be positioned above the convection exhaust. This is to prevent hot air collecting 
in the recess closest to the ceiling. The seal must a maximum of 100 mm above the convection exhaust’s upper edge and must be made up 
of 20 mm thick building boards made of calcium silicate or a panel with at least a 50 mm thickness of rock wool on top.

Convection air

The convection air ventilates the surround, cools the insert and transports the hot air out into the room. The total sum of the effective 
cross section area up and down must not be less than the stated values. The air intake must be positioned somewhere between floor level 
and the bottom of the insert, at the front or on the sides of the recess. The vent must be positioned above the insert’s highest point at the 
front or to the sides of the recess. 
If the air intake respectively the vent is positioned on the sides, the areas for the left respectively right sides must be the same size
to ensure that the insert is evenly cooled.
Check the minimum distance to the ceiling.

Convection air in: 200 cm² 
Convection air out: 200 cm²

Load bearing base

Check that the convection box is positioned on a base strong enough to bear the weight of the stove and chimney. The weight of the 
chimney must not load the insert with more than 100 kg. The base must not prevent the convection air flow in the area between insert and 
recess.

 

Recessing the insert

When recessing the insert, adjacent walls that are not classed as fire walls or are considered unsuitable for heat loads must be protected by 
non-combustible material according to the specification below. 
All joints on the non-combustible material must be sealed using the method recommended by the manufacturer. The area between the 
insert and the recess must be ventilated according to the specification/dimension diagrams.
When top connecting a steel flue, please refer to the particular manufacturer's installation instructions. Observe the safety distance to 
combustible material required by the steel flue Heat radiation from the door is strong and because of this combustible material must not be 
placed closer than 1 m in front of the door. When recessing, the building material must not be in direct contact with the insert due to the 
thermal expansion of the insert.

Material requirements

The building material must not be combustible. 
The thermal conductivity coefficient 

λ 

must be a maximum of 0.14 W/mK. 

The thickness of the building material must always be at least 100 mm. 
In cases where the building material’s insulation properties are given as a U-Value, this must be a maximum of 1.4 W/ m²K.

List of suitable materials:
Aerated concrete: 

λ

 

= 0.12–0.14 

Vermiculite: 

λ

 

= 0.12–0.14 

Calcium silicate: 

λ

 

= 0.09

Heat shield

Содержание C i6

Страница 1: ...www contura eu C i6 Installation instruction Lighting instructions...

Страница 2: ...F 29 12 3029 The undersigned is responsible for the manufacture and conformity with the declared performance Niklas Gunnarsson Business area manager NIBE STOVES Markaryd 1st July 2013 DECLARED PERFORM...

Страница 3: ...gular chimney sweeping services WARNING The insert becomes very hot During operation certain surfaces of the insert become very hot and can cause burn injury if touched Also take heed of the strong he...

Страница 4: ...the installation is carried out by an authorised technician Contact one of our dealers who can recommend suitable fitters Building permission Before installing a stove or erecting a chimney it is nec...

Страница 5: ...ter diameter is 125 mm The insert requires a draft in the chimney of at least 12 Pa The draft is affected both by the length and area of the chimney and by how well sealed it is The minimum recommende...

Страница 6: ...The weight of the chimney must not load the insert with more than 100 kg The base must not prevent the convection air flow in the area between insert and recess Recessing the insert When recessing th...

Страница 7: ...earing base The dimensions are the minimum dimensions unless otherwise stated Wall of non combustible material that is not in contact with combustible material and therefore has no minimum thickness r...

Страница 8: ...ATION The insert is designed to be installed as a stove cassette in existing approved open hearths There must be an 8 mm air gap around the insert to allow for the expansion of the insert when hot Ins...

Страница 9: ...2 1 3 GB 105 Hearth bottom Hearth cladding Fire bars Remove internal loose cast iron components and fire bricks as follows INSTAllATION Removing the internal parts Handle the hearth cladding with care...

Страница 10: ...4 5 1 2 3 GB 106 INSTAllATION Then remove the insert from the convection box...

Страница 11: ...ase of installation sold as an accessory Secure the sleeve in the hose Connect and seal carefully between the hose and the chimney according to the separate instruction The insert can also be connecte...

Страница 12: ...x6 LE K 6 mm 1 2 3 GB 108 INSTAllATION...

Страница 13: ...tallation is inspected by an authorised inspection body before the insert is used Also read the Lighting instructions before lighting for the first time Final inspection of the installation Reinstall...

Страница 14: ...air can be reduced The nominal output of 5 kW is obtained when the combus tion air damper is 50 open and two logs are lit In this operating position it is important that the air intake damper is fully...

Страница 15: ...nt or a special soot removal agent to remove it Such agents can be purchased from regular hardware stores or from your local stove dealer Never use cleaning agents that contain any abrasives these can...

Страница 16: ...content of the wood ensure that you have good base embers and go through the lighting instructions one more time Smoke odour around the insert for periods This can occur when wind blows down the chimn...

Отзывы: