Installation distance to walls and ceiling
* To prevent discolouration of painted fire walls, we recommend the same side distance as to combustible walls.
INSTALLATION DISTANCES
The minimum distance in front of
the stove opening to combustible
parts of the building or interior
decoration must be at least 1 m.
The dimension diagrams only
show the minimum permitted
installation distances for the
stove. When connecting to a steel
flue, also note the safety distance
requirements of the flue. The
safety distance between an un-
insulated flue and a combustible
part of the building should be at
least 300 mm.
550
1600
mi
n 2300
105
220
Air inlet Ø64
Combustible roof
430
430
1050
1140
167
120
Hole in foot plate Ø120
368
150
729
781
Combustible wall
267
100
415
435
435
690
Combustible wall
Permitted area for
combustible parts
of the building
268
50
629
900
900
640
Fire-retardant wall of
brick or concrete
217
50
700
1100
50*
325*
Fire-retardant wall of
brick or concrete