![Controls MVP-A3238 Скачать руководство пользователя страница 21](http://html1.mh-extra.com/html/controls/mvp-a3238/mvp-a3238_product-manual_2658930021.webp)
CONTROLS, INCORPORATED
C O N T R O L S Y S T E M S & S O L U T I O N S
- 20 -
Module Regen Buttons
The MVP module has two regeneration function buttons, Regen Request and Regen Inhibit.
Regen Request – This button will operate when a required regen has been annunciated by the ECU
and subsequently denied by the Operator. The module will repost the ECU regen request every 2
minutes, however, if at any time prior to the prompt, the operator wishes to reinstitute the regen
prompt, it can be done by pressing this button for at least two seconds. If the operator presses this
button at any time when the ECU does not require a regen, a message of No Regen Required will
appear.
Regen Inhibit – Pressing this button for at least two seconds will alternate the module between the
Regen Inhibit and Regen Auto Modes. If at any time the ECU indicates a regen is required and the
unit is in Regen Inhibit mode, a prompt screen will appear asking if the operator wants to switch to
auto.
Parked Regeneration Process
When a regen is required, the ECU sends a signal to the controller lighting the DPF Lamp. This lamp
will remain on until a regen has been completed.
The display will annunciate several prompts for the Operator’s acknowledgement. The controller will
prompt the Operator that a regen is needed. To proceed, the operator will press the Enter button
for yes.
DPF
Lamp