background image

                                           CONTROLS, INCORPORATED 

C O N T R O L   S Y S T E M S   &   S O L U T I O N S  

                                                                                                            

                                                                                                                  - 7 - 

CONTROL PANEL ANALOG AND DIGITAL INPUTS 

The panel has one analog input and one digital input available to monitor other components, 
senders or signals.  These inputs can be used for a number of purposes including alarms and shut 
downs. Two digital inputs are pre-set for external throttle control.   

 

Input 

Heading 

Default 

Options 

Connector 

Pin 

Analog 1 

Function 

 

Fuel level 

Digital 1 

Normally 

Open 

Open / Closed  

 

 

Function 

None 

 

Message 

None 

 

Check 

Off 

Off / Always / Run 

Digital B1 

Function 

Throttle Up 

 

Digital B2 

Function 

Throttle Down 

 

Digital B5 

Function 

None 

 

 

Содержание MVP-305

Страница 1: ... MVP 305 Revision 2 1 ______________________________________________________________________________________________________________________________________ Copyright Controls Inc P O Box 368 Sharon Center OH 44274 Phone 330 239 4345 Fax 330 239 2845 www controlsinc com ...

Страница 2: ...TALLATION INFORMATION 3 MODULE CONNECTORS 4 ENGINE ALARMS CODES AND MESSAGES 5 ENGINE ECU ALARMS DE RATE SHUT DOWNS ALARM ANNUNCIATION AND CODE READER PANEL INDICATION LAMPS ACTIVE AND STORED ENGINE ECU CODES CONTROL PANEL ANALOG AND DIGITAL INPUTS 7 MENU SYSTEM 9 MENU ACCESS EXIT AND NAVIGATION MENUS TO VIEW INFORMATION MENUS TO CONFIGURE MODULE SETTINGS ...

Страница 3: ...s are available in the CAN CONFIGURATION MENU Throttle Settings The following bolded settings are required for manual and automatic operation in the Throttle Configuration menu Throttle Configuration Throttle Type Selection TSC Minimum Speed TSC Maximum Speed TSC Ramp Rate Throttle Curve Selection Manual Throttle Options 1 Vernier Throttle Vernier throttle is standard up and down throttle between ...

Страница 4: ...CONTROLS INCORPORATED C O N T R O L S Y S T E M S S O L U T I O N S 3 INSTALLATION INFORMATION ...

Страница 5: ...RPORATED C O N T R O L S Y S T E M S S O L U T I O N S 4 MODULE CONNECTORS 5V SUPPLY ALARM THROTTLE DOWN THROTTLE UP DIGITAL INPUT 3 BATTERY BATTERY CAN high CAN LOW E STOP FUEL LEVEL BATTERY 1 2 3 4 5 6 1 2 3 4 5 6 ...

Страница 6: ...s the engine ECU that de rates or shuts down the engine when it is not operating within normal parameters This includes more common shut downs like high engine temperature and low oil pressure but can encompass a large range of parameters depending on the ECU Alarm Annunciation and Code Reader This panel is configured to operate with standard J1939 engines where engine de rate and shutdowns are ma...

Страница 7: ...Codes The panel also provides the ability to check the engine ECU for all ACTIVE and STORED engine ECU codes These codes can be viewed via the Active Codes and Stored Codes menus Engine Alarm Fault Lamp Engine Warning Lamp Regen Active Lamp DPF Lamp Regen Inhibit Lamp Low DEF Lamp Malfunction Lamp Wait to Start Lamp ...

Страница 8: ...als These inputs can be used for a number of purposes including alarms and shut downs Two digital inputs are pre set for external throttle control Input Heading Default Options Connector Pin Analog 1 Function Fuel level A 5 Digital 1 Normally Open Open Closed A 4 Function None Message None Check Off Off Always Run Digital B1 Function Throttle Up B 4 Digital B2 Function Throttle Down B 3 Digital B5...

Страница 9: ...r Sender ground must be common with battery negative 5 Oil Pressure VDO PSI Oil pressure in PSI can be measured and displayed using a standard Stewart Warner scale sender of 10 ohms 180 ohms 10 0 PSI and 180 150 PSI Sender ground must be common with battery negative 6 Oil Pressure bar Oil pressure in bar can be measured and displayed using a standard Stewart Warner scale sender of 10 ohms 180 ohms...

Страница 10: ...scroll menu options Press UP arrow button to enter menu Press DOWN arrow button to reverse Exit Menu System Hold MENU button and press ENTER button To Change a Setting Press ENTER button to bring up brackets Press UP arrow button and DOWN arrow button to change setting Press ENTER button to make selection brackets disappear Recycle key to the OFF position after changing a setting ...

Страница 11: ...odes Engine Parameters View ECU Engine Information Load Torque Oil Temp etc Engine Identification Engine Model View Engine Serial View Module Information Control Unit Part View Control Unit Software Version View Controller Setup Quick Setup 1 PASSWORD PROTECTED Engine Parameter Configuration 2 Input Configuration 3 Output Configuration 4 Throttle Configuration 5 Module Configuration 6 Display Conf...

Страница 12: ... Configure Selection Channels Message Digital 1 7 Function 4 Output Configuration Configure Selection Channels Message Relay 1 Function Default to Clutch 5 Throttle Configuration Throttle Type TSC Mode TSC Minimum Speed TSC Maximum Speed TSC Bump Speed TSC Ramp Rate Throttle Curve Multi State Speeds 1 4 6 Module Configuration Low Power Mode Power Save Delay Pre Alarms Displayed Clear Number of Sta...

Страница 13: ...essage 10 Emissions Configuration DEF Level Check Default Off Low DEF Pre Alarm Default 16 Low DEF Alarm Default 0 DEF Alarm Delay Allow Service Regeneration Yes No Deere Only Regeneration Interlock On Off TSC Transmit Yes No stop TSC to engine during regeneration DPF Inhibit Lamp Source 11 Clutch Configuration Clutch 1 Engage Trip Default None Clutch 1 Engage Speed Default 800 rpm Clutch 1 Engage...

Отзывы: